Fluid: air
Operation: double motion induction type
Operation ambient temperature range: -10 - 70 degree celsuis
Bore size: 25mm
Stroke: 50mm
CHANTO Air Cylinder DD25X50
There is no price at present, you can Request a Quote
People who bought this item also viewed
MINDMAN Air Cylinder MCMB-11-40-75-A
CKD Air Cylinder SCPG2-M-00-10-30
CHANTO Air Cylinder RC16X180
CHANTO Air Cylinder ASR160X500
CHANTO Air Cylinder AQ2R80X75FA
CHANTO Air Cylinder ASR160X150
Festo Air Cylinder ADN-125-15-I-P-A
CKD Air Cylinder RV3S50-180-45
Festo Air Cylinder DNU-32-150-PPV-A
SHAKO Air Cylinder DR10B55
HENGSTLER Encoder RI30-O/500AR.34TA
TPC Solenoid Valve DV1220-5H
SIEMENS Actuator GAP196.1E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Rexroth Piston Pump A4VSO125LR2/30R-VPB25N00
IFM Sensor MX5050
HENGSTLER Encoder RI76TD/10000AH.4N20TF
SHAKO Air Cylinder IC80B350
Recent related posts
-
08/19/2020
What kind of expansion valve should be used for industrial chiller selection
1. When industrial chiller manufacturers produce air-cooled or water-cooled chillers, they generally use external balance thermal expansion valves when selecting thermal expansion valves.
-
06/30/2023
Cooling Systems Compared: Inverter AC vs Fixed Speed AC - Which One Should You Choose?
Air conditioning systems have become an essential part of our daily lives, providing relief from the oppressive heat and humidity of summer.
-
03/01/2021
The main difference between brushless DC motor and DC servo motor
Different definitions: (1) Brushless DC motor is a typical mechatronics product, which is composed of motor body and driver. Brushless motor refers to the motor without brush and commutator (or collector ring), also known as commutator less motor. As early as the 19th century, when the motor was born, the practical motor was the brushless form, that is, the AC squirrel cage asynchronous motor, which has been widely used. However, the asynchronous motor has many insurmountable defects, so that the development of motor technology is slow. The transistor was born in the middle of last century, so the brushless DC motor using transistor commutation circuit instead of brush and commutator came into being. This new type of brushless motor is called electronic commutation DC motor, which overcomes the defects of the first generation of brushless motor.
-
03/03/2021
The key detection items of servo motor and common problems in servo motor detection
1).Servo motor detection -- cogging torque: Cogging torque is an inherent phenomenon of permanent magnet motor, which can make the motor torque fluctuate and produce vibration and noise. We measure the change of motor torque in a rotation cycle on a special test bench and analyze the distribution of cogging torque.
-
07/03/2020
Building & Construction Hold Over 20 % Share in Portable Air Compressor Market 2019 to 2027
LOS ANGELES, United States: QY Research published latest market research report on global Mute Oil Free Air Compressor market 2020 with industry detail study, growth analysis, latest and future trends, leading companies analysis, regional analysis and forecast by 2026.
-
05/02/2022
How Do The Components of Surge Protector Work?
Surge protector is composed of five parts: discharge gap, discharge tube, varistor, suppression diode and choke coil which includes at least one nonlinear voltage limiting element.
-
07/23/2020
The influence of capillary tube length on refrigeration system parameters and troubleshooting
The capillary tube generally refers to a slender copper tube with an inner diameter of 0.4~2.0mm. As the throttling mechanism of the refrigeration system, the capillary tube is the simplest one. Because of its low price and flexible selection, it is widely used in small refrigeration devices.
-
09/11/2020
Thrust bearings
Thrust bearing: Rolling bearing mainly used for bearing axial load, its nominal contact angle is 45-90 degrees. According to the difference of nominal contact angle, it is divided into:
-
09/08/2020
Air compressor solenoid valve function
Solenoid valves are the basic components of automation used to control fluids and belong to experimental devices. Solenoid valves are not limited to hydraulic or pneumatic; solenoid valves for air compressors are usually used in industrial control systems to adjust the direction, flow, speed, on-off and Other parameters.
-
06/20/2020
Installation instructions for explosion-proof air conditioners
Installation instructions for explosion-proof air conditioners <img src="{{media url="Installation_instructions_for_explosion-proof_air_conditioners.jpg"}}" alt="" /> 1. The power supply of the explosion-proof air conditioner shall have a dedicated line, and a circuit breaker or air switch shall be provided in the dedicated line. The power supply wires and fuses should comply with the relevant regulations and cannot be changed at will.