Fluid: air
Operation ambient temperature range: 0-60 degree celsius
Bore size: 40mm
Stroke: 700mm
CHELIC Pneumatic Equipment Air Cylinder MRU40*700-SD2
People who bought this item also viewed
CHELIC Air Cylinder JD16*20-B
CHELIC Air Cylinder JCB25X30-SD2
CHELIC Air Cylinder JD20*10-B
Festo Air Cylinder DSNU-10-40-P-A
Festo Air Cylinder DNC-40-320-PPV-A
Festo Air Cylinder AEVULQ-16-10-P-A
Festo Air Cylinder ADVC-50-10-A-P-A
HENGSTLER Encoder RI76TD/2048ED.4N24RF
Belimo Actuator LR24A-S
SMC Proportional Valve ITV3050-33F4L4
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
OMRON Relay G3NE-210TL 24VDC
SKF Oil Seal 18x28X7 HMS5V (NBR)
Yaskawa Servo Motor SGMAH-04AAF4S
Recent related posts
-
06/25/2020
Classification of air-conditioning compressors
The air-conditioning compressor plays the role of compressing and driving the refrigerant in the air-conditioning refrigerant circuit. The working circuit is divided into an evaporation area (low pressure area) and a condensation area (high pressure area). The indoor unit and outdoor unit belong to the high-pressure or low-pressure area (depending on the working state), and the compressor is generally installed in the outdoor unit.
-
01/14/2022
Case Studies of How to Replace a Compressor in Refrigerator (Part Two)
As we have mentioned in the first part, it’s the refrigeration capacity, the clean piping system, and the drying filter that deserve our attention.
-
06/14/2020
Cold storage equipment installation and commissioning
Installation of refrigeration compressor unit in cold storage: The condensing unit should avoid installing in high temperature environment, and the outdoor awning should be installed to avoid rain or direct sunlight. The air inlet side of the air-cooled c 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬
-
03/16/2023
The Installation and Maintenance of Water Pump
1.Check whether the water pump motor is in good condition. 2.Good airtightness should be ensured between water pump and pipeline.
-
06/09/2023
AC Making Noise When off: Where is the Noise from and What to Do?
If you’ve ever heard your AC making noise when off, it can be a bit unnerving. You may wonder what's causing the noise and what you can do to fix the problem.
-
08/20/2020
Emergency shutdown treatment for sudden cooling water cut
During the operation of refrigeration equipment, accidents of sudden cooling water interruption sometimes occur. The cause of this accident is generally the failure of the cooling water pump.
-
08/11/2020
What are the parts of the electrical installation of cold storage engineering installation
The electrical installation of cold storage engineering can include overhead lines, lighting, cables, machine room wiring, workshop or factory area power transformation and distribution.
-
06/14/2020
How to choose the matching type of cold storage
A, high temperature cold storage (± 5 ℃): suitable for the preservation of fruits and vegetables; B. Medium temperature cold storage (-10 ℃ ~ -5 ℃): suitable for food refrigeration after freezing; C, low temperature cold storage (-20 ℃ ~ -10 ℃): sui 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘
-
12/22/2022
How to Maintain Optical Fiber Amplifiers?
An optical fiber amplifier (OFA) can not only directly amplify optical signals, but also have the advantages of real-time, high gain, online, low noise and low loss.
-
06/29/2020
Compressor protection measures against liquid strikes
Compressor protection measures against liquid strikes When too much liquid enters the cylinder and it is too late to discharge it from the exhaust valve, a liquid blow will occur in the cylinder. The high pressure generated during the liquid blow damages the cylinder, piston, connecting rod, etc., so it is necessary to take a Series of protective measures.