Chigo Air Conditioner KFR-35GW-C104+N3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SHAKO Air Cylinder TCD80C200
MALLORY Capacitor 630V 0.27UF
MAHLE Filter KL1173
Autonics Rotary Encoder E40H8-400-2-N-24
KOYO PLC SH2-64R1
Recent related posts
-
08/13/2020
The difference between ammonia refrigeration and fluorine refrigeration system
The vapor compressor refrigeration system can adopt a variety of methods for refrigeration, such as fluorine refrigeration and ammonia refrigeration. What are the differences and differences between the two methods?
-
07/16/2020
Vacuum leak test method for small cold storage equipment
Refrigeration systems with evaporating pressure gauges close to or below atmospheric pressure must be tested for vacuum leak tests, leaving the refrigeration equipment under proper vacuum for a certain period of time, reflecting and observing whether air has penetrated into the system from the reading of the vacuum pressure gauge for inspection The sealing performance of the cold storage equipment system.
-
08/02/2020
How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage.
-
06/21/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
-
07/10/2020
What is the working principle of screw air compressor
What is the working principle of screw air compressor The screw-type single-stage compression air compressor is composed of a pair of yin and yang rotors (or screws) that are parallel to each other and rotate in the cylinder, so that the air between the rotor slots continuously produces periodic volume changes,
-
05/12/2022
Ultra3000 Servo Drive Failure Repair
We have listed the common faults and repair methods of Ultra3000 servo drives, if you need to replace the equipment, we provide <a href="https://okmarts.com/servo-product/allen-bradley-serve-product.html" alt="Allen Bradley Rockwell Servo Drive, Ultra3000 Servo Drive Repair">Allen Bradley Rockwell Servo Drive</a>
-
07/29/2020
Analysis of the seven major causes of air-conditioning freezing, the idea should be correct, and the troubleshooting should be accurate and fast~
Small split air conditioners often have icing in the indoor unit evaporator in summer. Why does it freeze and how to eliminate it? Here are the following:
-
06/30/2020
Copeland compressor What is multi-stage compression why
Copeland compressor What is multi-stage compression why Copeland Compressor is a major brand of our Gaolun Compressor and one of the most popular products. A lot of understanding of the basic knowledge of the compressor can help us use it better. One of the compressor concepts is called "multi-stage compression". I don't know if you have any idea?
-
07/27/2020
What should I do if the compressor burns out?
Why does the compressor burn the motor? What is the cause of the burn-in phenomenon? A summary of the reasons for motor burn-in can be divided into: load, power supply, motor insulation, and lack of equivalence.
-
01/13/2021
Causes and solutions of gas stove solenoid valve not working
Causes and solutions of gas stove solenoid valve not working 1. The automatic extinguishing function of the gas stove solenoid valve fails, and the wiring gasket in the valve body cannot be energized, resulting in the gas stove solenoid valve not worki 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ӧ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ