How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage. Wait for failure.
At present, the air discharged from the indoor unit and pipeline is mostly ejected by the refrigerant of the outdoor unit:
01) Open the air pipe connecting the pipeline between the indoor unit and the outdoor unit;
02) Use a hexagon wrench to open the valve of the two-way stop valve on the outdoor unit to ensure that the refrigerant can enter the indoor unit pipeline;
03) As the refrigerant slowly enters the indoor unit pipeline, the refrigerant gradually occupies the pipeline, ejects the gas in the indoor unit pipeline, and discharges it from the opening of the disconnected thick pipe (trachea);
04). When the refrigerant is seen to be discharged, quickly connect the air pipe to the three-way shut-off valve, tighten the holder, and the exhaust operation is completed.
Note:
1) The 30s exhaust time mentioned here is just a reference value. In actual operation, the exhaust time must be controlled by feeling whether the sprayed gas is getting cold.
2) Mastering the exhaust time is very important for the use of air conditioners, because the exhaust time is too long, the refrigerant in the refrigeration system will be excessively lost, which will affect the cooling effect of the air conditioner; the exhaust time is too short, The air in the indoor unit and pipeline is not exhausted, which will also affect the cooling effect of the air conditioner.
3) Inverter air conditioners must be evacuated by vacuuming, because this type of air conditioner mostly uses R410a refrigerant. This refrigerant is mixed in strict accordance with a certain proportion. If part of the gas is discharged by the headspace method, the proportion of the refrigerant will change and affect the refrigeration effect (after about one year of use, the effect on the refrigeration effect is obvious), so it cannot The refrigerant headspace method is adopted.
How to use refrigerant to empty the air conditioner after installation
Recent related posts
-
08/02/2020
How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage.
-
08/02/2020
Air conditioning refrigerant specific classification and price
In the refrigeration device, there must be a working fluid in which the state changes and completes the thermodynamic cycle process.
-
08/02/2020
Summary of parameters and phenomena of air conditioning refrigerationheating system
Summary of parameters and phenomena of air conditioning refrigerationheating system 1. R22 refrigeration working state parameters (1) During summer cooling, the normal low pressure of the refrigeration system is between 0.4~0.59MPa.
-
08/02/2020
Principle and maintenance method of air conditioner pressure protector
In addition to window air-conditioning units, many air-conditioning systems use high-pressure and (or) low-pressure pressure protectors to protect the compressor in the event of a system failure. During the normal operation of the device
-
08/02/2020
How to debug McQuay air conditioner noise
Noise caused by thermal expansion and contraction when the wall-mounted machine is working: The noise caused by the stepper motor and the synchronous motor. The main reason is that the internal gears of the motor are poorly matched to form abnormal noise.
-
08/02/2020
When air conditioners lack fluoride, five common leak detection methods will teach you who don’t understand!
When the air conditioner is lack of fluoride, the detection of leaks is the primary task of leakage repair. Today we introduce five common leak detection methods for you, namely fluorescent leak detection, soapy water leak detection
-
08/02/2020
Treatment method after load damage of screw chiller
First of all, we must confirm whether the compressor load has been burned or the components have been worn away. If so, the refrigerant system will inevitably be contaminated. For example, residual refrigerant oil remains in the pipeline after carbonization
-
08/02/2020
How to quickly calculate the cost of cold storage
Factors that determine the price of cold storage<br></br> cold storage unit: (cold storage unit size, cold storage unit brand, cold storage unit origin, cold storage unit type).
-
08/02/2020
Basic principles of data center cooling and energy saving solutions
Each data center has its own characteristics, so there is no technical solution that can be applied to any data center. This document mainly discusses some basic principles and technical issues in data center cooling and energy saving.
-
08/02/2020
What is the four-pipe air conditioner Under what circumstances
Four-pipe air-conditioning means that the air-conditioning box is equipped with cold coils and hot coils at the same time. Each group of coils is fed one time, a total of four, so it is called four-pipe.