Ue400 with rated working voltage (v)
The rated limit breaking capacity (kA) Icu AC50Hz 400V 50
The rated running breaking capacity (kA) Ics AC50Hz 400V 50
The minimum value of the rated residual switching-on and switching-off capacity I△m is 25%Icu. Twelve point five
Use category a.
Total life expectancy with load and no load 3000/17000/20000
Tripper type thermomagnetic type
The residual operating current (adjustable in the fourth gear) I △ n (a) x1: 0.05/0.1/0.2/0.5; X2:0.1/0.3/0.5/1
Breaking time (adjustable in third gear) Total breaking time (s) T1: 0.3/0.5/1
Weight (kg) 3P/4P 2/3.5
NM8 or NM8S plastic casing circuit breakers are NM8L and NM8SL residual current operated circuit breakers
after being assembled with residual current protection modules conveniently. NM8L and NM8SL series residual
current operated circuit breakers are mainly used in circuits with AC 50Hz, rated voltage up to 400V and
rated current up to 630A A.. Its main function is to provide indirect contact protection for fatal personal
electric shock, and at the same time, it can also be used to prevent electrical fire caused by ground fault
current. It can be used to protect the overload, short circuit and undervoltage of the line, and can also be
used for infrequent switching of the line.
NM8L: Thermomagnetic Residual Current Action Circuit Breaker
NM8SL: Intelligent Residual Current Action Circuit Breaker
Shell level 100A 250A 630A
The rated current (a) is 16, 20, 25, 32, 4050, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 630
Note: the maximum value of thermomagnetic residual current operated circuit breaker is 500A A.
3 means 3 poles
4 means 4 poles
4A indicates that the N pole is not equipped with an overcurrent release element, and the N pole is always on;
4B indicates that the N-pole is not equipped with an overcurrent release element, and the N-pole and the other
three poles are combined and divided together (the N-pole is combined first and then divided)
4C indicates that the N pole is equipped with an overcurrent trip element, and the N pole is closed and divided
together with the other three poles (the N pole is closed first and then divided), and the operating current is 1.0In;;
4D indicates that the N pole is equipped with an overcurrent tripping element, and the N pole is always on, and the
operating current is 1.0In;;
M: No code for motor protection: power distribution protection
Normal working conditions and installation conditions
The altitude of the product installation site is 2000m and below;
The external magnetic field of the installation site of residual current operated circuit breaker shall not
exceed 5 times of the earth magnetic field in any direction;
The action value of the intelligent release is not affected by temperature fluctuation. However, the maximum
allowable current of residual current operated circuit breaker is still the same as that of circuit breaker
Environmental temperature.
Damp-heat: the relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is
+40℃, and it can be higher at lower temperature. The monthly average maximum relative humidity in the wettest month is
90%, at the same time. The monthly average minimum humidity in this month is +25℃, and the condensation on the
product surface due to temperature change is considered.
Pollution level: the pollution level is level 3
Characteristics
Using splicing modular design, users can install and maintain themselves without affecting the characteristics
of circuit breakers;
With power indication;
The residual action current and the breaking time of the residual current can be adjusted, which is convenient
for users to choose;
With residual current action indication and reset button, users can quickly judge the action reason of residual
current action circuit breaker.
In addition, the residual current operated circuit breaker cannot be closed without confirming and eliminating
the leakage fault (the reset button is not pressed);
The residual current operated circuit breaker equipped with auxiliary switch can remotely indicate the tripping
of the circuit breaker in case of leakage fault;
High breaking ability and no arcing;
With isolation function and reliable contact indication
Isolation position is in "0" (off) position;
Only when the contact is fully opened can the operating handle indicate the "0" (OFF) position;
Padlocks can only be installed when the contacts are opened;
Rotating the handle will not change the reliability of contact indication;
The isolation function shall ensure the mechanical reliability indicated by the contact, no residual current,
and the terminal on the power supply side can withstand high impact voltage;
Isolation function
Chint Circuit Breaker NM8L-100S/3
There is no price at present, you can Request a Quote
People who bought this item also viewed
Chint Circuit Breaker NM1LE-250S/4300A
Terasaki Circuit Breaker XE50NS
Siemens Circuit Breaker 3RV1021-0JA10
Siemens Circuit Breaker 3RV2023-4AA10
COOPER Transformer VP2-0116-R
Shilin Contactor S-P16 36V
Ferraz Shawmut Fuse PC44UD75V16CTQ
ANLY Relay AH2-YB AC220V
UniOhm Resistor 1206W4F9100T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FZ 1354-M2
Yaskawa Servo Motor SGMPS-01ACA2B
FULOS Air Cylinder SDAS50-10-B
SHAKO Air Cylinder ICB40C500
SMC Solenoid Valve VP3165V-065GB1
ABB Circuit Breaker S201M-B2
Recent related posts
-
04/23/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV430~SV449)
FANUC Servo Amplifier Alarm Codes and Troubleshooting Methods
-
07/05/2020
Hitachi water source heat pump compressor
How does the air conditioning compressor work? The air-conditioning compressor is also called a rotary (rotor) compressor, and its working principle is to rely on an eccentric rotor under the action of spring force, the compressor, and the eccentric rotor are always in contact with the container separated by the sliding container Changes to achieve a process of compression. When the eccentric rotor rotates, the volume of the container changes and the gas is compressed.
-
07/05/2020
PORTABLE AIR COMPRESSOR MARKET SWOT ANALYSIS BY GROWTH AND FORECAST FROM 2020-2026|STANLEY BLACK&DECKER,POWERMATE,CAMPBELL HAUSFELD,SENCO
DataIntelo report titled Global Centrifugal Air Compressor Market provides detailed information and overview about the key influential factors required to make well informed business decision. This is a latest report, covering the current COVID-19 impact on the market.
-
04/24/2022
How to Install Float Level Meter?
Float level meter is a continuous liquid level measuring instrument with simple installation and reliable operation.
-
06/29/2020
What are the causes treatment and prevention methods of compressor liquid blow
What are the causes, treatment and prevention methods of compressor liquid blow Liquid blow means that the refrigerant liquid or wet steam is sucked into the compressor by the compressor due to failure or insufficient absorption of heat, which is called liquid blow. First, the main reasons are as follows:
-
09/14/2020
Explosion-proof human body static eliminator; explosion-proof human body static eliminator, petroleum-specific human body static eliminator
CM-003 touch static elimination ball, its appearance is made of stainless steel tube and stainless steel ball, it is suitable for chemical, metallurgy, military, oil field, fireworks, computer room, high-end hotels, high-end offices and other flammable and explosive places.
-
01/26/2024
Computer Room Air Conditioning: Work Principle, Characteristics and Technical Requirements, Benefits
Computer room air conditioners (CRACs), to put it simply, are air conditioners dedicated to computer rooms.
-
07/18/2020
The core heart of the chiller-compressor
Power compressor is indispensable when refrigeration equipment is cooling. Such as chillers, chromatography freezers, ice machines, ultra-low temperature refrigerators, etc., their driving force is the refrigeration compressor, the entire refrigerant cycle is the refrigeration compressor
-
06/29/2020
Analysis of the cause of excessive suction temperature of compressor
Analysis of the cause of excessive suction temperature of compressor The high suction temperature is mainly due to the increase of superheat of suction. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam. Under normal circumstances, the compressor cylinder head should be half cold and half hot. If the suction temperature is too high, the cylinder head will all heat up.
-
08/20/2020
Winter cold resistance air conditioner, floor heating, radiator who is the most expensive
Time flies, it’s already November in a blink of an eye. I heard that this year is a cold winter. I don’t know what kind of heating method your home chooses. Today I will count the number with okmarts.com editor,