There is no price at present, you can Request a Quote
The rated limit breaking capacity (kA) Icu AC50Hz 400V 50
The rated running breaking capacity (kA) Ics AC50Hz 400V 50
The minimum value of the rated residual switching-on and switching-off capacity I△m is 25%Icu. Twelve point five
Use category a.
Total life expectancy with load and no load 2000/14000/16000
Tripper type thermomagnetic type
The residual operating current (adjustable in the fourth gear) I △ n (a) x1: 0.05/0.1/0.2/0.5; X2:0.1/0.3/0.5/1
Breaking time (adjustable in third gear) Total breaking time (s) T1: 0.3/0.5/1
Weight (kg) 3P/4P 2.6/4
NM8 or NM8S plastic casing circuit breakers are NM8L and NM8SL residual current operated circuit breakers
after being assembled with residual current protection modules conveniently. NM8L and NM8SL series residual
current operated circuit breakers are mainly used in circuits with AC 50Hz, rated voltage up to 400V and
rated current up to 630A A.. Its main function is to provide indirect contact protection for fatal personal
electric shock, and at the same time, it can also be used to prevent electrical fire caused by ground fault
current. It can be used to protect the overload, short circuit and undervoltage of the line, and can also be
used for infrequent switching of the line.
NM8L: Thermomagnetic Residual Current Action Circuit Breaker
NM8SL: Intelligent Residual Current Action Circuit Breaker
Shell level 100A 250A 630A
The rated current (a) is 16, 20, 25, 32, 4050, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 630
Note: the maximum value of thermomagnetic residual current operated circuit breaker is 500A A.
3 means 3 poles
4 means 4 poles
4A indicates that the N pole is not equipped with an overcurrent release element, and the N pole is always on;
4B indicates that the N-pole is not equipped with an overcurrent release element, and the N-pole and the other
three poles are combined and divided together (the N-pole is combined first and then divided)
4C indicates that the N pole is equipped with an overcurrent trip element, and the N pole is closed and divided
together with the other three poles (the N pole is closed first and then divided), and the operating current is 1.0In;;
4D indicates that the N pole is equipped with an overcurrent tripping element, and the N pole is always on, and the
operating current is 1.0In;;
M: No code for motor protection: power distribution protection
Normal working conditions and installation conditions
The altitude of the product installation site is 2000m and below;
The external magnetic field of the installation site of residual current operated circuit breaker shall not
exceed 5 times of the earth magnetic field in any direction;
The action value of the intelligent release is not affected by temperature fluctuation. However, the maximum
allowable current of residual current operated circuit breaker is still the same as that of circuit breaker
Environmental temperature.
Damp-heat: the relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is
+40℃, and it can be higher at lower temperature. The monthly average maximum relative humidity in the wettest month is
90%, at the same time. The monthly average minimum humidity in this month is +25℃, and the condensation on the
product surface due to temperature change is considered.
Pollution level: the pollution level is level 3
Characteristics
Using splicing modular design, users can install and maintain themselves without affecting the characteristics
of circuit breakers;
With power indication;
The residual action current and the breaking time of the residual current can be adjusted, which is convenient
for users to choose;
With residual current action indication and reset button, users can quickly judge the action reason of residual
current action circuit breaker.
In addition, the residual current operated circuit breaker cannot be closed without confirming and eliminating
the leakage fault (the reset button is not pressed);
The residual current operated circuit breaker equipped with auxiliary switch can remotely indicate the tripping
of the circuit breaker in case of leakage fault;
High breaking ability and no arcing;
With isolation function and reliable contact indication
Isolation position is in "0" (off) position;
Only when the contact is fully opened can the operating handle indicate the "0" (OFF) position;
Padlocks can only be installed when the contacts are opened;
Rotating the handle will not change the reliability of contact indication;
The isolation function shall ensure the mechanical reliability indicated by the contact, no residual current,
and the terminal on the power supply side can withstand high impact voltage;
Isolation function
Chint Circuit Breaker NM8L-250S/3
There is no price at present, you can Request a Quote
People who bought this item also viewed
Chint Circuit Breaker NM1LE-250S/4300A
Siemens Circuit Breaker 3RV1021-1CA10
Siemens Circuit Breaker 3RV2011-1KA10
Terasaki Circuit Breaker S1000-CE
TRIAD Transformer F-250X
Moeller Contactor DILM185(-S)
OBO Surge Protection Device V20-1-280
Raychem Fuse RXE050
SONGCHUAN Relay 896H-1CH-C1-12VDC
Yageo Resistor RSF3WSJT-73-7K5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
IXYS Rectifier Module VUO82-18N07
Kompass Vane Pump VQ215-75-11-FR
COKERY Belt HTD 1025-5M
NORGREN Air Cylinder M/31082
Toshiba Compressor BH240X2CS-20KU
Recent related posts
-
07/28/2023
Heat Pump Making Loud Noise in Cold Weather: Causes and Solutions
When the temperature drops outside, your heat pump becomes an essential part of your home's heating system. While it's common for heat pumps to make some noise during operation, loud or unusual noises can be a cause for concern.
-
09/22/2020
Thyristor solid medium voltage soft starter
I. Overview In our country's coal mine, petroleum, chemical industry, steel, power generation, water supply, cement building materials and other fields, there are a large number of 3KV, 6KV, 10KV and other voltage levels of medium and high voltage AC asynchronous motors. A large part of them do not require speed regulation, but need to solve the starting problem of these high-voltage large motors.
-
01/23/2023
What is a Pressure Transmitter?
A pressure transmitter is a device that converts pressure into pneumatic or electric signals for control and remote transmission.
-
09/14/2020
The exhaust temperature of the unit is high (over 100℃)
The lubricating oil level of the unit is too low (the green position should be visible from the oil level mirror);
-
08/20/2020
Placement of the thermostatic valve bulb
The bulb should be as close as possible to the outlet of the evaporator and placed in close contact with the outlet pipe. In the part of the pipe section where the temperature bulb is in contact with the pipe,
-
06/13/2020
What are the classifications of air filters What are the classification criteria of air filters
Air filter classification standard What are the classification of air filters according to working principle Air filter can be divided into compressed air filter, primary effect filter, medium efficiency filter, high efficiency filter and ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ
-
04/03/2023
Top 10 Industrial Compressor Manufacturers in the World
The so-called compressor is a kind of machinery that compresses low-pressure gas to high-pressure gas, and it provides power for refrigeration cycles, gas transportation or pneumatic tools, etc.
-
11/02/2023
What is a Rotary Screw Air Compressor? Everything You Need to Know
Rotary screw air compressor (screw air compressor, screw type air compressor, rotary screw compressor), is a positive displacement air compressor
-
10/30/2023
Understanding Split System Air Conditioners: Definition, Workings, Pros, Types and More
When it comes to cooling your home or office, split system air conditioners have become increasingly popular. These systems offer efficient and effective cooling while providing comfort and control.
-
07/06/2020
Global Commercial Refrigeration Compressors Market Trends, Opportunities, Drivers, Challenges and Porter’s Five Forces Analysis
JUL 6, 2020 Corona Effect, Covid-19 Commercial Refrigeration Compressors Market, Global Commercial Refrigeration Compressors Industry, Global Commercial Refrigeration Compressors Industry Forecast 2026, Global Commercial Refrigeration Compressors Market, Global Commercial Refrigeration Compressors Market 2020, Latest Commercial Refrigeration Compressors Market Research Report