There is no price at present, you can Request a Quote
The rated limit breaking capacity (kA) Icu AC50Hz 400V 50
The rated running breaking capacity (kA) Ics AC50Hz 400V 50
The minimum value of the rated residual switching-on and switching-off capacity I△m is 25%Icu. Twelve point five
Use category a.
Total life expectancy with load and no load 1500/8500/10000
Tripper type intelligent
The residual operating current (adjustable in the fourth gear) I △ n (a) x1: 0.05/0.1/0.2/0.5; X2:0.1/0.3/0.5/1
Breaking time (adjustable in third gear) Total breaking time (s) T1: 0.3/0.5/1
Weight (kg) 3P/4P 2.6/4
NM8 or NM8S plastic casing circuit breakers are NM8L and NM8SL residual current operated circuit breakers
after being assembled with residual current protection modules conveniently. NM8L and NM8SL series residual
current operated circuit breakers are mainly used in circuits with AC 50Hz, rated voltage up to 400V and
rated current up to 630A A.. Its main function is to provide indirect contact protection for fatal personal
electric shock, and at the same time, it can also be used to prevent electrical fire caused by ground fault
current. It can be used to protect the overload, short circuit and undervoltage of the line, and can also be
used for infrequent switching of the line.
NM8L: Thermomagnetic Residual Current Action Circuit Breaker
NM8SL: Intelligent Residual Current Action Circuit Breaker
Shell level 100A 250A 630A
The rated current (a) is 16, 20, 25, 32, 4050, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 630
Note: the maximum value of thermomagnetic residual current operated circuit breaker is 500A A.
3 means 3 poles
4 means 4 poles
4A indicates that the N pole is not equipped with an overcurrent release element, and the N pole is always on;
4B indicates that the N-pole is not equipped with an overcurrent release element, and the N-pole and the other
three poles are combined and divided together (the N-pole is combined first and then divided)
4C indicates that the N pole is equipped with an overcurrent trip element, and the N pole is closed and divided
together with the other three poles (the N pole is closed first and then divided), and the operating current is 1.0In;;
4D indicates that the N pole is equipped with an overcurrent tripping element, and the N pole is always on, and the
operating current is 1.0In;;
M: No code for motor protection: power distribution protection
Normal working conditions and installation conditions
The altitude of the product installation site is 2000m and below;
The external magnetic field of the installation site of residual current operated circuit breaker shall not
exceed 5 times of the earth magnetic field in any direction;
The action value of the intelligent release is not affected by temperature fluctuation. However, the maximum
allowable current of residual current operated circuit breaker is still the same as that of circuit breaker
Environmental temperature.
Damp-heat: the relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is
+40℃, and it can be higher at lower temperature. The monthly average maximum relative humidity in the wettest month is
90%, at the same time. The monthly average minimum humidity in this month is +25℃, and the condensation on the
product surface due to temperature change is considered.
Pollution level: the pollution level is level 3
Characteristics
Using splicing modular design, users can install and maintain themselves without affecting the characteristics
of circuit breakers;
With power indication;
The residual action current and the breaking time of the residual current can be adjusted, which is convenient
for users to choose;
With residual current action indication and reset button, users can quickly judge the action reason of residual
current action circuit breaker.
In addition, the residual current operated circuit breaker cannot be closed without confirming and eliminating
the leakage fault (the reset button is not pressed);
The residual current operated circuit breaker equipped with auxiliary switch can remotely indicate the tripping
of the circuit breaker in case of leakage fault;
High breaking ability and no arcing;
With isolation function and reliable contact indication
Isolation position is in "0" (off) position;
Only when the contact is fully opened can the operating handle indicate the "0" (OFF) position;
Padlocks can only be installed when the contacts are opened;
Rotating the handle will not change the reliability of contact indication;
The isolation function shall ensure the mechanical reliability indicated by the contact, no residual current,
and the terminal on the power supply side can withstand high impact voltage;
Isolation function
Chint Circuit Breaker NM8SL-250S/3
There is no price at present, you can Request a Quote
People who bought this item also viewed
Chint Circuit Breaker NM1LE-250S/4300A
Terasaki Circuit Breaker S800-CF
Terasaki Circuit Breaker XS630SE
ABB Circuit Breaker 2CDS251001R0045
Delixi Transformer QZB-300KW
ALBRIGHT Contactor SW80-6
Littelfuse Fuse KLKD4
Fuji Relay TK-E3M-C
UniOhm Resistor 25121WJ0363T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
IFM Optical Fiber Amplifier OO5003
ADDA Fan AQ0912HB-A71GL
CKD Air Cylinder SRL3-00-25B-1250
Festo Air Cylinder DZH-32-120-PPV-A
Recent related posts
-
07/09/2020
Air Compressor Market in APAC – Industry Analysis and Growth Forecast to 2024
Asia Air Compressor Market ASEAN air compressor market size is expected to reach $1.13 billion by 2024, registering a CAGR of 3.6% during the forecast period. The major factors stimulating the market growth includes growing automotive industry and increasing investments in construction industry in the region.
-
08/19/2020
How to choose refrigerant for different types of industrial chillers
We all know that the working temperature of medium and high temperature chillers can be controlled between 3°C and 35°C, low temperature chillers can also be controlled between 0°C and -60°C,
-
01/26/2022
A Quick Look at the Submersible Pressure Transmitter
Submersible pressure transmitters use imported chip assembly, reflecting the superior technology. Their structure is compact and firm and is light for installation.
-
08/26/2020
Features of scroll refrigeration compressor:
Advantages of scroll refrigeration compressors:<br></br> 1. There is no reciprocating mechanism, so the structure is simple, small in size, light in weight, few parts (especially few wearing parts), and high reliability;<br></br>
-
09/12/2023
Hydronic Heat Pump Explained (Definition, Working Principle, Pros and Cons)
Hydronic heat pumps are a type of heat pump that are becoming increasingly popular in residential and commercial settings. They offer a number of advantages over traditional heating and cooling systems, including increased efficiency, reduced energy costs, and improved air quality.
-
08/04/2020
Why is the compressor short of oil, and why does the evaporator have an oil film
The compressor is a complex machine that runs at high speed. Ensuring adequate lubrication of the compressor crankshaft, bearings, connecting rods, pistons and other moving parts is the basic requirement for maintaining the normal operation of the machine
-
08/28/2020
How to identify whether the gas storage tank is a simple pressure vessel
Simple pressure vessels that meet the following conditions at the same time do not need to go through the registration procedures.
-
09/21/2020
Development Trend of Domestic Screw Refrigeration Compressor
Since the advent of screw compressors in 1934, after decades of technological improvement, screw compressors have been widely used, especially in refrigeration.
-
09/09/2020
Installation method to ensure that the air compressor does not leak oil
1. Install the gasket correctly: The gasket between the parts of the air compressor functions as a leak-proof seal. If the material, production quality and installation do not meet the technical specifications, it may cause oil leakage.
-
07/05/2020
Full analysis of high-temperature burn-down failure of scroll compressor
Full analysis of high-temperature burn-down failure of scroll compressor Scroll compressor overheating at high temperature for a long time will not only reduce the insulation performance and reliability of the motor, shorten the life of the motor, but also reduce the lubricating ability of the lubricating oil, and even cause carbonization and acid hydrolysis of the lubricating oil.