Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 40 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 32...40 A |
Circuit breaker size S2 for motor protection, CLASS 10 A-release
9.5...14 A N-release 208 A screw terminal increased switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 12.5?W
at AC in hot operating state per pole 4.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
9.5?...?14?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 14?A
operating current
at AC-3
at 400 V rated value 14?A
operating power
at AC-3
at 230 V rated value 3?000?W
at 400 V rated value 5?500?W
at 500 V rated value 7?500?W
at 690 V rated value 11?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 10?kA
at 690 V rated value 5?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 18?kA
at AC at 690 V rated value 8?kA
response value current
of instantaneous short-circuit trip unit 208?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 14?A
at 600 V rated value 14?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 1.5?hp
at 230 V rated value 3?hp
for three-phase AC motor
at 200/208 V rated value 5?hp
at 220/230 V rated value 5?hp
at 460/480 V rated value 10?hp
at 575/600 V rated value 15?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 100
at 500 V 80
at 690 V 63
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Siemens Circuit Breaker 3RV2032-4SA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1021-4BA15
Siemens Circuit Breaker 3RV1031-4GB10
Siemens Circuit Breaker 3VL5763-2AA36-0AA0
Siemens Circuit Breaker 3RV2011-1FA10
Eaton Moeller Circuit Breaker MFD-CP8-NT
Fuji Circuit Breaker BW32SAG-3P010
Bel Signal Transformer DP-241-5-12
Schneider Contactor LC1E9511
OBO Surge Protection Device VF24-AC/DC
Edison Fuse MCL8
Fuji Relay HH54PW-L
VISHAY Resistor LTO150F10000JTE3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Hitachi Compressor ASH244GV-C8LU
Northman Piston Pump PMV18-A3-R-10
USING Solenoid Valve FPR-MGKS12-03-01
Yuken Safety Valve MBW-03-H-20
ARK Air Cylinder KAND-25-5-A-P-A
Recent related posts
-
07/19/2020
Advantages and disadvantages of screw refrigeration compressors
Screw refrigeration compressor is a rotary positive displacement compressor. It uses the change of the cogging volume and position of the screw to complete the process of vapor suction, compression and exhaust. Oil-free screw compressors came out in the 1930s, mainly used to compress air. Later, the oil-injected screw compressor appeared in the cylinder,
-
07/30/2020
Reason analysis of refrigeration compressor can not start or stop soon after start
First check the main circuit. Whether the power supply has electricity, whether the voltage is normal, whether the fuse has been blown due to starting overload, whether the air switch has tripped,
-
06/14/2020
Design and selection of compressor unit for mobile cold storage
1. Regardless of the brand selection of the compressor unit, it is determined according to the evaporation temperature of the active cold storage and the effective working volume of the cold storage. In addition, the condensation temperature of the frozen 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ
-
06/14/2020
Tips for energy saving in refrigeration systems
Tips for energy saving in refrigeration systems Screw refrigeration compressor When setting the cooling capacity of the compressor, avoid the operating range of low energy efficiency ratio; for the refrigeration system with a large range of operating co 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب
-
02/08/2023
Pros and Cons of Pneumatic, Electric and Hydraulic Actuators
The actuator used in the control valve are nothing more than pneumatic, electric, and hydraulic (electro-hydraulic) type.
-
04/15/2024
13 Common Servo Motor Faults: Causes and Troubleshooting Methods
Servo motor is a device that can convert electrical energy into mechanical energy. It can accurately control speed and position and is an important part of the servo system.
-
09/09/2020
What are the criteria for the selection of air compressors
When choosing an air compressor, we actually need to pay attention to some principles, so that we can compare and choose the one that is more suitable for us. Today, the company will give the company that needs an air compressor, etc., let’s talk about what we should pay attention to when choosing an air compressor. matter.
-
08/16/2020
Can the chiller use a descaling agent for descaling
In fact, the use of a descaling agent for descaling is a common practice for the descaling work of the chiller. Therefore, the chiller can completely use the descaling agent for descaling. This is not a problem.
-
08/02/2020
Refrigerator refrigeration system leak detection
The refrigeration system should be tested for leaks due to refrigerant leakage or refrigerators after replacing parts. The following three methods are generally used for leak detection in refrigeration systems
-
06/14/2020
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor