Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 40 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 32...40 A |
Circuit breaker size S2 for motor protection, CLASS 10 A-release
35...45 A N-release 650 A screw terminal increased switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 24.5?W
at AC in hot operating state per pole 8.2?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 50?000
of auxiliary contacts typical 50?000
electrical endurance (switching cycles)
typical 50?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
35?...?45?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 45?A
operating current
at AC-3
at 400 V rated value 45?A
operating power
at AC-3
at 230 V rated value 11?000?W
at 400 V rated value 22?000?W
at 500 V rated value 30?000?W
at 690 V rated value 37?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
operating current of auxiliary contacts at AC-15
at 24 V 2?A
at 230 V 0.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
at 60 V 0.15?A
at 110 V 0?A
at 125 V 0?A
at 220 V 0?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 8?kA
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 15?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 650?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 45?A
at 600 V rated value 45?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 3?hp
at 230 V rated value 10?hp
for three-phase AC motor
at 200/208 V rated value 15?hp
at 220/230 V rated value 15?hp
at 460/480 V rated value 40?hp
at 575/600 V rated value 50?hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current
Ik < 400 A)
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 240 V none required
at 400 V 125
at 500 V 100
at 690 V 80
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 140?mm
width 55?mm
depth 149?mm
Siemens Circuit Breaker 3RV2032-4VA15
People who bought this item also viewed
Siemens Circuit Breaker 3RV1011-1BA10
Siemens Circuit Breaker 3RV1021-0AA10
Siemens Circuit Breaker 3RV1041-4JA15
Siemens Circuit Breaker 3RV1021-0GA10
Fuji Circuit Breaker CP30FM-1P001
Siemens Circuit Breaker 3RV2021-0JA10
Siemens Circuit Breaker 3VL5763-2AA36-0AA0
Siemens Circuit Breaker 3RV1011-1EA10
TRIAD Transformer F-112X
Hager Contactor ES430
Delixi Fuse RT16-00 20A
JK Relay JKAC3C40A-2B75
EBG Resistor HXP-600-450R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Siemens Sensor 3RG4054-0AF30
PIZZATO Switch FG 60ED5D0Z-F21
KCL Vane Pump SVQ215-75
MINDMAN Air Cylinder MCQV2L-11-63-80
Recent related posts
-
05/04/2023
What is Vapour Compression Refrigeration System?
Vapour compression refrigeration system (VCRS) is the most common cooling system used in modern refrigeration technology.
-
06/14/2020
Industrial refrigeration screw refrigeration compressor repair
Industrial refrigeration screw refrigeration compressor maintenance, screw refrigeration compressor has the following advantages:
-
03/16/2023
The Installation and Maintenance of Water Pump
1.Check whether the water pump motor is in good condition. 2.Good airtightness should be ensured between water pump and pipeline.
-
08/19/2020
How to choose the correct cold storage condenser
The condenser is one of the main heat exchange equipment in the cold storage refrigeration system, and its function is to cool and condense the high-temperature refrigerant superheated
-
06/10/2022
How To Replace A Solenoid Valve Coil?
The solenoid valve coil generates a magnetic field. This moves a ferromagnetic plunger inside the valve which opens or closes the valve. When a coil (solenoid) is defective, it can be difficult to find a replacement for the original.
-
06/14/2020
Today, a user who came to repair a display cabinet said that the compressor of the freezer sometimes works and sometimes does not work
Today, a user who came to repair a display cabinet said that the compressor of the freezer sometimes works and sometimes does not work.
-
06/18/2020
Main components of reciprocating compressor_Advantages and disadvantages of reciprocating compressor
Reciprocating compressor<img src="{{media url="wysiwyg/Main_components_of_reciprocating_compressor_1.jpg"}}" alt="" /> Reciprocating compressor refers to a type of compressor that reciprocates the piston or diaphragm in the cylinder to periodically change the volume of the cylinder and realize the pressurization and delivery of gas. It is a positive displacement compressor. According to the reciprocating components, it is divided into piston type and diaphragm type compressors.
-
06/20/2020
Working principle of air conditioner temperature controller
In the use of our home air conditioners, the most important function is to ensure that our indoor temperature is maintained at a relatively comfortable degree, and the air conditioner temperature controller is a tool to help us achieve this. What is the principle of controlling the temperature of our air conditioner by air conditioner? Today I will introduce some working principles and functions of air conditioner temperature controller for everyone to understand.
-
08/20/2020
Tips for cold storage installation that you don't know!
Now that the weather is getting hotter and hotter, many merchants in the catering industry have begun to attach great importance to the cold storage area, so today the editor of okmarts.com
-
09/05/2020
Top 10 tortures of frequency converters
There are ten major "tortures" of inverters today, which can also make your inverter suffer. Let's follow the editor of okmarts.com to explore the top ten "tortures" that will make your inverter "death than life"!