CLC Level Meter LG-200
People who bought this item also viewed
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SIEMENS Servo Motor 1PH7101-2NF02-0LA3-Z
Schneider Sensor XX230A11PA00M12
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KOMPASS Piston Pump PV080A3LM1A
Kompass Vane Pump 50T+50T-39+36-LR
Yaskawa Servo Motor SGME-A5AFNS12
ABB Circuit Breaker 10117674
Hitachi Compressor ASH218GN-C8LU
Recent related posts
-
01/07/2021
Why does the air conditioner frost
Why does the air conditioner frost Q: Why does frost occur when the air conditioner is running? Answer: When the air conditioner is performing heat pump heating operation, the surface temperature of the heat exchanger of the outdoor unit will be very 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵
-
02/18/2020
The principle of central air conditioning refrigeration
The principle of central air conditioning refrigeration The liquid Freon enters the evaporator through the capillary. The space suddenly increases and the pressure decreases. The liquid Freon will vaporize and absorb a lot of heat. The evaporator will become cold. The indoor unit fan will remove the indoor air from the evaporator. Blow through, so the cold air blows out from the indoor unit. Let's take a look at the cooling principle of the central air conditioner with the editor for your reference<img src="{{media url="magefan_blog/The_principle_of_central_air_conditioning_refrigeration.jpg"}}" alt="" />
-
06/14/2020
Popularly speaking, what is the difference between heating 24℃ and cooling 24℃
Popularly speaking, what is the difference between heating 24℃ and cooling 24℃ Everyday use of air conditioners must have this experience: in the summer, the air conditioner is used for cooling. Setting the temperature to 24°C makes the room very cool, a 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ
-
08/05/2020
Basic knowledge of air source heat pump at a glance
1. What is a heat pump?<br></br> Heat pump is not a water pump, or even a pump, but a complete set of equipment. The English name of heat pump, heatpump, has 2 definitions:
-
06/20/2020
Structure of multi-vane compressor_Characteristics of multi-vane compressor
Structure of multi-vane compressor_Characteristics of multi-vane compressor <img src="{{media url="Structure_of_multi-vane_compressor_Characteristics_of_multi-vane_compressor.jpg"}}" alt="" /> The sliding vane refrigeration compressor is a positive displacement rotary compressor. It can be divided into two types: single slide type and multi slide type. Multi-slider compressors are currently mainly used as low-pressure compressors with two-stage compressors.
-
06/29/2020
Time node of compressor refrigeration oil replacement
Time node of compressor refrigeration oil replacement 1. The long-term operation of the entire refrigeration system, after the initial maintenance, if there are no special circumstances, the compressor refrigeration oil should be replaced when the refrigeration system working time reaches 10,000-12,000 hours.
-
07/29/2020
6 possible reasons why the air conditioner is not cooling
6 possible reasons why the air conditioner is not cooling<br></br> The reasons why the air conditioner is not refrigerated are divided into non-air-conditioning faults and air-conditioning faults. Today we share the reasons for non-air-conditioning faults.
-
11/12/2021
Different Types of Pressure Transmitters, Working Principle, and How to Select Pressure Transmitter
Pressure transmitter is a kind of pressure measuring instrument widely used in many transmitters. It is widely used in petroleum, chemical, metallurgy, food, electric power, medicine, papermaking, textile and other industries.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/03/2021
How to Communicate PLC to VFD
PLC (Programmable Logic Controller) and VFD (Variable Frequency Drive) play an important role in industrial production and technological development.