Output mode: NA - NPN normally open
NB-NPN normally closed type
PA -PNP normally open
PB -PNP normally closed type
Outer diameter size: 12 Φ
Maximum sensing distance: 1202- 2mm ±10%
1204- 4mm ±10%
Safety sensing range: 1202- 0 ~ 1.6mm
1204- 0 ~ 3.2mm
Standard sensing object: 12 × 12 × 1mm
Hysteresis distance: 15% or less of operation distance
Power supply voltage: 10-30VDC
Current consumption: 10mA or less
Output current: Maximum sink current 150mA
Residual voltage: 1.5V or less (at 150mA sink current)
Response frequency: 1202- 1KHZ
1204- 600HZ
Shell material: Detection su
CONCH Switch TS-1202
People who bought this item also viewed
PILZ Switch PSEN sl-0.5p 1.1 1switch
Omron Switch D4B-2A71N
Kriwan Switch 3164918
ARK Air Cylinder KCXSM20-60
Siemens Sensor 3RG4023-0AG03-0AH0
Eaton Moeller Circuit Breaker NZMH4-VE800
Siemens Contactor 3RT2516-1AD00
SHOWA Overload Pump OLP8-H-R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SOG Oil Seal TB35*80*7
MINDMAN Air Cylinder MCJQ-11-63-20M
ITECH Power Supply IT7622
TCS Oil Seal TC 12*28*7
Recent related posts
-
02/15/2022
Factors Affecting Service Life of the Air Compressor Oil
Maintaining the air compressor oil is critical to the compressor’s performance.
-
08/13/2020
How to replace the lubricating oil and filter drier of the chiller
After the chiller is used for a long time, the lubricating oil will inevitably be contaminated or acidified. Therefore, we must pay attention to the change of oil quality during the operation of the unit.
-
06/29/2020
What is the cause of compressor pipeline vibration
-
07/16/2022
Common Faults of Gear Pump
Cause: A. the rotation direction is opposite; B. the suction or discharge valve is closed
-
08/09/2020
The meaning of pipe diameter De, DN, d, ф
The meaning of pipe diameter De, DN, d, ф<br></br> The respective ranges of De, DN, d, ф<br></br> De-- PPR, PE pipe, polypropylene pipe outer diameter<br></br>
-
08/03/2023
Why is My Heat Pump Freezing Up in Summer: Common Causes and Maintenance Tips
Heat pumps are an incredibly effective way to regulate indoor temperatures throughout the year. During the summer months, they work to cool your home by extracting heat from the indoors and dispersing it outside.
-
08/04/2020
Analysis of five major problems in current heating management
With the development of society and the continuous improvement of people's living standards, traditional heating methods and management models have become less and less suitable for the development of the times.
-
09/07/2020
The reason why permanent magnet compressor replaces electric tiger
Energy conservation is the theme of the development of this era. In this era, we will regard energy conservation as a reference value no matter what products we buy. In the past two years,
-
01/16/2021
Refrigeration compressors are divided into several categories according to the working principle
Refrigeration compressors are divided into several categories according to the working principle Refrigeration compressors can be divided into two types: volume type and speed type according to their working principles.
-
10/16/2023
Cold Storage Warehouse: Everything You Need to Know
With the increasing demand for fresh food products, the need for proper storage and preservation has become more important than ever.