Grating type:DW
Sensor type:Conventional type
Connection mode:Cable line
Series: 6 Flush or quasi flush
Output type: PNP NO
Shell: Cylindrical external threaded housing
Size:10
Contrinex Sensor DW-AD-603-M10E-637
People who bought this item also viewed
Contrinex Sensor DF-AD-604-C1717
Contrinex Sensor BD10-S3-M30-5M
Contrinex Sensor LHR-C23PA-PMS-301
Contrinex Sensor DF-AD-601-C1735
TAKEX Sensor AS-U20
YORK Sensor 025-29139-004
LIROJY Sensor LRE-3V1-S
Danfoss Transmitter 060G2111
Fireye Flame Detector MBPF-200S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Sanyo Denki Fan 109P0924H201
Eaton Contactor DILM38-10(110V50/60HZ)
SCHMERSAL Switch T2A067-02Y
C&G VFD Frequency Converter C10M-2.2T4
Parker Sporlan Expansion Valve WVE-135-CP100
Recent related posts
-
09/09/2020
Practical application of air compressor in various industries
1. Power industry Main uses: compressed air systems for instrumentation, compressed air systems for ash removal, factory miscellaneous compressed air systems, water treatment including boiler feed water treatment and industrial wastewater treatment systems, and equipment power compressed air systems in hydropower stations.
-
09/10/2020
Lubrication characteristics and requirements of mobile air compressors
1. The characteristics of the mobile air compressor are: (1) The mobile air compressor should be easy to move frequently, the working conditions are changeable, and the load changes greatly. (2) Mobile air compressors are mostly heavy-duty, medium-speed or low-speed transmission, and most require frequent starting and often withstand shock loads;
-
07/30/2020
What does the horse mean Is 1 horse 2350W or 2500W
Regarding the concept of "1 horse", some say it means the power consumption of the air conditioner, and some say it means the cooling power of the air conditioner. What the hell is that?
-
03/11/2023
Advantages of Motor Soft Starter
Motor is widely applied in industry and daily life, thus people attach more importance to the starting method of motor. Generally, motor soft starter should be used when motor working power exceeds 30 kilowatts
-
08/07/2020
Three circulation systems of industrial chillers
Water chillers play a very important role in the industry. They are needed in the refrigeration process of electroplating, chemical, printing, pharmaceuticals, plastics and other industries. Due to the wide range of applications of chillers
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/19/2022
What are the Main Parameters of a Molded Case Circuit Breaker?
Molded case circuit breakers can automatically cut off the current after the current exceeds the trip setting.
-
07/01/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Precautions for the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse. Because although the color of the compressor oil does not change on the surface, the consumption of additives may have exceeded the limit.
-
06/14/2020
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
-
06/14/2020
What are the causes of frost in refrigeration compressors
The importance of refrigeration compressors in the entire cold storage refrigeration system is self-evident, I believe everyone knows. Next look at the editor to teach you to turn around.