There is no price at present, you can Request a Quote
Body Type | Discus 6D |
Product Type | Discus |
App | LT |
Capacity BTU/HR | 93500 |
EER BTU/WH | 4.9 |
Freq-Phase-Voltage | 60-3-460 |
Ref | R22 |
Copeland Compressor 6DRXF11ME-TSK-C00
There is no price at present, you can Request a Quote
People who bought this item also viewed
Tecumseh Compressor TRK5518C
Tecumseh Compressor RK5512Y-NA3A
Danfoss Compressor MTZ80HP4AVE
Bristol Compressor H79A623DBVA
Copeland Compressor ZB58KQE-TFD-550
Copeland Compressor ZR144KCE-TFD-522
Copeland Compressor ZR34K3E-TFD-522
Copeland Compressor ZR125KCE-TFD-550
Copeland Compressor CRJQ-0300-TF5-522
Copeland Compressor CR37KQ-PFT-522
Tecumseh Compressor AWA5532EGH
Hitachi Compressor SG184SV-H6CUN
TRIAD Transformer VPS24-7300
Danfoss Expansion Valve 068U2324
Siemens Contactor 3RT1056-6SP36
Ebmpapst Fan D2E146-AP47-02
TAMAGAWA Electric Motor TS3624N1E2
PARKER Filter 9955-12-371H
Danfoss Sight Glass SGR 014-0002
SIEMENS Capacitor B25692S0128J800
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LEITZ Tool for Metal Cutting M8
Nidec Fan D08K-24TS1
SMC Solenoid Valve VQZ1421-5L1-M5
MASTER Industrial Heater B150
Schneider Contactor LC2D09Q7C
Recent related posts
-
07/01/2020
Why does the centrifugal Taikang compressor have such a high speed
Why does the centrifugal Taikang compressor have such a high speed Centrifugal compressors require speed during operation, and the speed is very high. However, many people do not understand, why does a centrifugal compressor need such a large speed? Let us take a centrifugal Taikang compressor as an example to explain this problem for everyone.
-
08/09/2020
Rosemount 3144P temperature transmitter FF fieldbus manual!
power supply Rosemount temperature transmitter FOUNDAIION fieldbus uses standard fieldbus power supply. The operating voltage of the transmitter is 9 to 32Vdc with a maximum of 11 mA. The rated voltage at the transmitter end is 42.4V dc, Wiring diagram
-
08/08/2020
What kinds of systems are there for central air conditioning Which is better for home installation
What kinds of systems are there for central air conditioning Which is better for home installation For owners who want to decorate their new home, air conditioning may be an essential part of building a comfortable home.
-
02/27/2023
Types and Characteristics of Common Air Cylinders
Types and Characteristics of Common Air Cylinders, Pen Cylinder, Thin Cylinder, Free Mounting Cylinder, Double-Shaft Cylinder, Slide Cylinder, Rodless Cylinder
-
06/14/2020
How to properly maintain the refrigeration compressor
How to properly maintain the refrigeration compressor 1. Frequently check whether there are debris or even conductive objects in the motor, whether the coil is damaged, and whether the stator and rotor are rubbed, otherwise the motor will burn out after ﰸ2 䀀 ᅵ皥
-
08/20/2020
How to judge the fault based on the indicator light of the ice machine
1. The power indicator light keeps flashing quickly and the machine does not work: The cause of the failure: the water temperature probe is open. Repair method: Open the rear cover, open the cover of the electric control box above the compressor, find a three-core connector, check if there is any dropout or poor contact, then reconnect it.
-
09/21/2020
Development Trend of Domestic Screw Refrigeration Compressor
Since the advent of screw compressors in 1934, after decades of technological improvement, screw compressors have been widely used, especially in refrigeration.
-
03/03/2021
The key detection items of servo motor and common problems in servo motor detection
1).Servo motor detection -- cogging torque: Cogging torque is an inherent phenomenon of permanent magnet motor, which can make the motor torque fluctuate and produce vibration and noise. We measure the change of motor torque in a rotation cycle on a special test bench and analyze the distribution of cogging torque.
-
08/15/2020
Steps to determine the cause of the failure of the thermal expansion valve
1. When the refrigerant of the refrigeration system leaks completely, or there is no refrigerant flowing through the thermal expansion valve due to other reasons, the valve body of the thermal expansion valve will not be frosted.
-
07/31/2020
Five common problems of refrigeration system
Trouble phenomenon: The cooling effect of the whole machine is poor, the water outlet is only slightly cool, and the pressure on the high pressure side and the low pressure side are found to be low when checked with the manifold pressure gauge (under the normal speed of the compressor