There is no price at present, you can Request a Quote
Body Type | CR Compressor |
Product Type | Copelaweld |
App | AC |
Capacity BTU/HR | 36400 |
EER BTU/WH | 10.4 |
Freq | 60Hz |
Phase | 3Ph |
Voltage | 200/230 |
Ref | 22 |
Copeland Compressor CR37KQ-TFC-267WB
There is no price at present, you can Request a Quote
People who bought this item also viewed
Sanyo Compressor C-SBN453H8A
Tecumseh Compressor TRK5518C
Hitachi Compressor ASL155SN-C7EU
Daikin Compressor 2YC45ZXD
Copeland Compressor ZR72KC-TFD-523
Copeland Compressor ZB38KQ-TFD-558
Copeland Compressor ZB26KQE-PFJ-558
Copeland Compressor ZP67KCE-TFD-420
Sanyo Compressor C-RV222H81BB
Bristol Compressor H22B243ABK
Sanyo Compressor C-SC673H8H
Daikin Compressor JT90VABY1L
Wurth Transformer 750311486
Saginomiya Expansion Valve ATX-57080DUS
Siemens Contactor 3RT1054-1AU36
Ebmpapst Fan 4600Z
Crouzet Electric Motor 82867012
Danfoss Sight Glass SGI 10S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Keyence Sensor LR-ZH500C3P
SKF Oil Seal 15X25X5 HMSA10 V(FKM)
PARKER Filter QU130-25
Donaldson Filter P502494
TECO PLC AP-340BR-A
Recent related posts
-
12/07/2023
How to Distinguish Different Types of Fans in Data Centers
Without fans, it is impossible to ensure that equipment components operate at a constant temperature. Long-term continuous high-temperature operation of equipment will accelerate the aging of components and shorten the life cycle of equipment operation.
-
08/20/2020
Placement of the thermostatic valve bulb
The bulb should be as close as possible to the outlet of the evaporator and placed in close contact with the outlet pipe. In the part of the pipe section where the temperature bulb is in contact with the pipe,
-
08/19/2020
5 common causes of refrigeration system failures and solutions
1. The suction temperature is too high-mainly caused by the increase of suction superheat. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam.
-
08/27/2020
Do you know the distress signal of screw air compressor
The screw air compressor will inevitably have various problems during long-term use, and an alarm will be triggered at this time. Especially in the high temperature in summer, screw air compressors are more likely to appear frequently.
-
06/07/2022
What is A Solenoid Coil?
The solenoid coil generally refers to the inductive coil, which is wound on the insulating tube by the wires. The wires are insulated from each other.
-
09/07/2020
The essentials of air compressor selection
When buying an air compressor, in addition to the purchase cost, how to reduce electricity expenses? How to extend the service life of the air compressor? How to provide air pressure smoothly?
-
06/14/2020
315, counterfeit refrigeration compressors, valves, and refrigerants Compressor articles: counterfeit and hardest hit areas
In the field of commercial refrigeration compressors, the form and content of the cottage are very complicated and relatively hidden. It is common to buy second-hand compressors from the second-hand market, make a facelift, refurbish and label them for sa 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ѷ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ
-
09/08/2020
What environment will affect the operation of the air compressor
The surrounding environment of the air compressor will also have a significant impact on the operation of the air compressor. The following phenomena are mainly caused by the analysis of the cause of the failure caused by the bad surrounding environment, so the user should try to meet the standard requirements when installing the air compressor to deal with the surrounding environment .
-
06/25/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
07/10/2020
Hitachi central air conditioners are really strong. A few words about how powerful are Hitachi compressors
Hitachi central air conditioners are really strong. A few words about how powerful are Hitachi compressors. I saw many articles about Hitachi compressors, various parameters and terminology, and simply summarized the following points