The surrounding environment of the air compressor will also have a significant impact on the operation of the air compressor. The following phenomena are mainly caused by the analysis of the cause of the failure caused by the bad surrounding environment, so the user should try to meet the standard requirements when installing the air compressor to deal with the surrounding environment .

   1. Poor environmental ventilation and heat dissipation. There are three main situations in which the surrounding environment of the air compressor affects heat dissipation: one is that it is too close to wall-like obstacles; the other is that there are other heat sources near the air compressor, and the third is that the front door and side door are open during operation, and the fan cannot form strong airflow.

  2, the radiator is blocked. When the surrounding environment of the air compressor is dusty, long-term operation will cause a layer of dust or sludge to adhere to the surface of the radiator, and the internal copper pipes are also easy to block due to the accumulation of grease, which affects the heat dissipation effect.

   3. The oil filter is too dirty. This machine has 3 side-by-side oil filters. When they are too dirty, the resistance oil cannot enter the compressor at the normal flow rate. The compressor will quickly heat up due to insufficient cooling and lubricating oil. When the pressure difference between the inlet and outlet oil exceeds 0.18MPa, the filter element needs to be replaced.

   4. The cooling oil level is too low. When the cold machine is checked, if the oil level is lower than the lower end of the inspection tube, it should be replenished immediately. Low oil mark or poor oil quality. The machine uses the manufacturer’s special compressor oil. When other low-grade or inferior oils are used, the viscosity and specific heat will not reach the standard and the temperature will be too high.

   5. The fan tape is broken or loose. When the tape breaks, the air compressor will stop automatically when the temperature is too high after running for about 5 minutes. If the tape is too loose, it will slip, which will reduce the fan speed and affect heat dissipation. At this time, the tightness of the fan tape should be replaced or adjusted.

   6. The oil cutoff valve is out of order. There is an oil cut-off valve between the oil filter and the compressor. When the oil cut-off valve cannot be opened, due to no oil lubrication and cooling, the temperature of the compressor rises rapidly after starting, and it will automatically stop after about 1 minute. Remove the temperature plug at the exhaust end of the compressor, you will find that the plug is dry and oil-free, and blue smoke will flow out of the hole. Open the maintenance hole at the bottom of the air compressor, remove the oil shut-off valve, and gently move the valve stem with your fingers to see if it can be pushed back and forth and can be easily reset. If it is difficult to move or return, the shutoff valve needs to be disassembled. If there is grease on the valve stem or valve hole, it needs to be polished with fine sandpaper until it can slide easily; if the spring is broken or there is a foreign body stuck in the letter, it will also affect the movement of the valve stem. At this time, you need to replace the spring or clean the spring and spring seat.