There is no price at present, you can Request a Quote
Copeland Compressor ZH150KCE-TEM-522
There is no price at present, you can Request a Quote
People who bought this item also viewed
Sanyo Compressor C-7RZ233H1A
Mitsubishi Compressor RHV135FCC
Mitsubishi Compressor TB33YLLMC
Carrier Compressor 06DR241BCC06C0
Copeland Compressor ZPD61KCE-TFD-433
Copeland Compressor ZR47KC-PFJ-522
Copeland Compressor ZR108KFE-TFD-522
Copeland Compressor ZR72KC-TFD-523
Samsung Compressor UG4T200FUAE4
GMCC Compressor HSM195V1UFT
Hitachi Compressor E605DH-59D2YG
Rechi Compressor 44R273A
WOONYOUNG Transformer WY21-100A
Danfoss Expansion Valve 068Z3417
Siemens Contactor 3RT2036-3XF44-0LA2
Nidec Fan W40S12BS2E5-57
ASLONG Electric Motor A58SW31ZY
PALL Filter AB2NFZ7PH4
Danfoss Sight Glass SG5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ABB Circuit Breaker 10236166
STULZ Air Conditioner CCU200CW
Nemicon Encoder NOC-S2000-2MD-8-050-00E
KOYO Absolute Rotary Encoder TRD-MA512N
Recent related posts
-
03/11/2022
Is It Necessary to Replace Your Refrigerator Compressor?
The compressor is like the heart of humans, which plays a vital role in the refrigerator. A compressor is key to improve the performance of your refrigerator.
-
06/14/2020
What to do if the screw chiller compressor is damaged
The compressor is the core component of the chiller. Damage to the compressor is a serious fault that needs to be dealt with in time, otherwise the chiller will not work. Today, the editor will introduce the knowledge and process of handling damaged screw 器2 䀀
-
08/17/2020
Too high or too low oil pressure of industrial chillers affects normal operation
When using industrial chillers, regular inspection and maintenance work is essential. In the absence of basic maintenance and regular inspections, many industrial chillers are prone to different failures.
-
08/08/2020
Maintenance knowledge and failure methods of small combined cold storage
1. The cold storage door is not closed tightly. Please adjust the distance between the hinge and lock on the door and the storage body.
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
07/02/2020
Meiyoule compressor MTZ-100 latest promotion
Meiyoule compressor MTZ-100 latest promotion Product Features of MYO100 Compressor: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably. 2. The high-performance standard bearings and motors of Meyer compressors can adapt to the use of new chlorine-free refrigerants.
-
08/08/2020
How much electricity does a 1.5-hp air conditioner need to work for 10 hours a night
How much electricity does a 1.5-hp air conditioner need to work for 10 hours a night When the indoor temperature reaches the preset temperature, as long as the outdoor compressor and electric fan stop running, the indoor cabinet electric fan will continueﰨ2 䀀
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/20/2020
The difference between cross-flow cooling tower and counter-flow cooling tower
The so-called cross-flow cooling tower is a type of cooling tower that allows air to flow horizontally through the water spray filler, and the water dragon falls vertically from the top of the tower
-
09/28/2023
Water Chiller for Ice Bath Explained: Working Principle, Pros and Cons, Application
Ice baths have been used for centuries as a form of therapy to reduce inflammation, relieve pain, and improve recovery time. Ice baths work by constricting blood vessels, which reduces blood flow and inflammation in the affected area.