Product type: Miniature Linear Guide
Special Rail: Standard rail
Rail dimension: 9
Rail type: Wide
Block type: Standard
Rail material: Standard rail
EU: End seal + Reinforcement plate + Stainless bottom seal
CPC Linear Guideway MR9WNEU
People who bought this item also viewed
SBC Linear Guideway SBI25SL-K1
HIWIN Linear Guideway HGW35CCZ0C
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Banner Sensor Q25RW3RE
Mitsubishi Circuit Breaker NFC100-CMX 3P
Recent related posts
-
06/14/2020
Does air conditioning and refrigeration rely on compressors or refrigerants, or both?
Does air conditioning and refrigeration rely on compressors or refrigerants, or both? This question seems to be asking whether to boil water in a kettle, whether it needs boiling water or a kettle. The compressor is a kettle, and the refrigerant is water 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/27/2023
Industrial Water Chiller Repair: Troubleshooting and Maintenance Tips
An industrial water chiller is a critical component in many manufacturing and industrial processes. It is responsible for cooling various types of equipment, which helps to prevent overheating and maintain optimal performance.
-
08/14/2020
What is the hazard of high temperature to compressor motor and lubricating oil
The heat generated by the compressor during normal operation should not cause overheating. Normal motor heating, compression heat and friction heat have been carefully considered when designing the compressor,
-
07/02/2020
How is the compression process of the PFM compressor
How is the compression process of the PFM compressor One of the PFM compressors is a scroll compressor. How is its compression process completed? We can find the answer in this article. First of all, we must know that there are two scrolls in the upper part of the PFM compressor, a moving scroll and a static scroll.
-
08/03/2020
Why do air conditioners, refrigerators, washing machines, etc. use three-wire plugs
Three-wire plug: neutral wire, live wire, ground wire. The ground wire belongs to the type of leakage protection! High-power electrical products are protected by three-phase plugs
-
08/07/2020
What should I do if there is water in the refrigerator compartment
In our daily life, many household appliances are used very frequently, but when encountering some emergencies, they feel helpless and have to ask after-sales or repair personnel for help.
-
07/18/2020
Explanation of the excellent performance of each component of the screw chiller
The application of screw refrigeration compressors is becoming more and more common, and some of them have entered the period of frequent failures. When the abrasion of the female and male rotors, body, and exhaust end seat of the refrigeration compressor reaches above 0.65rnm, vibration will occur when the refrigeration compressor is running, the sound is abnormal, the cooling capacity is reduced, and the compressor cannot work normally.
-
01/09/2022
Heat Pump Compressor Troubleshooting
There are various types of compressors used in the heat pump unit and the fully enclosed piston compressor is the most commonly used type. However, when it’s in winter, there most probably are faults of this type of compressor due to frequent heating operations.
-
06/30/2020
Correct handling method of single compressor
Correct handling method of single compressor The handling of a single compressor is very particular and has strict requirements, that is to say, it is not how you want to move it.