Connections:Gasket mount type
Nominal diameter: 3/8
Spool operating method:Spring offset type (with A solenoid)
Maximum operating pressure MPa {kgf/cm2}:35 {350}(25 {250}) *1
Maximum flow rate L/min:160 (DC), 130 (AC)
Permissible back pressure MPa {kgf/cm2}: 16 {160}
Maximum switching frequency times/minute
AC, DC:240
With rectifier:120
With built-in surge killer DIN connector type with lamp:60
External coating protection:IEC Pub529 IP65
Daikin Solenoid Valve KSO-G03-20AD-20
People who bought this item also viewed
CKD Solenoid Valve GAG412-1-0-B-AC110V
Honeywell Solenoid Valve VE4025B1045
Daikin Solenoid Valve KSO-GO2-2DA-30-E
Daikin Solenoid Valve KSO-G02-20AN-30
Daikin Solenoid Valve KSO-G02-4CA-20-EN
Daikin Solenoid Valve JSC-G01-2A-10
Contrinex Sensor BD2.5-P1-M12S
Delixi Contactor CDC1-250
FESTO Check Valve GRLA-1/2-QS-8-RS-D
KRACHT Overflow Valve HVFE50C2F1B40
NACHI Piston Pump PVS-2B-45N2-U-T-4255A
YI-SHING Vane Pump VHIF-40-140
HYDROMAX Gear Pump HGP-33A-L3030L
TAISEI Filter TSF-12-100W
Danfoss Sight Glass SGI 19S
SAMXON Capacitor 450V 270UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Contrinex Sensor DW-AS-703-M30-109
HIWIN Linear Guideway HGL35CAZAC
Dwyer Flowmeter RSF025V
Sanyo Denki Fan 109L1224H102
Recent related posts
-
09/14/2020
Common troubleshooting methods for twin screw compressors
Common troubleshooting of twin screw compressor 1. Trouble phenomenon The exhaust temperature of the unit is high (over 100 degrees) The coolant level of the unit is too low (should be visible in the oil glass but not more than half) Dirty oil cooler
-
06/20/2020
Composition principle of refrigeration system of refrigerator
Composition principle of refrigeration system of refrigerator Refrigerators have a larger cooling capacity than household refrigerators, and there are more refrigerants filled in the system. Therefore, a liquid storage tank is installed on the pipeline between the condenser and the filter, and a shut-off valve is installed on the tank to shut down the system for a long time. When closing the shut-off valve, the refrigerant liquid is stored in the tank.<img src="{{media url="Composition_principle_of_refrigeration_system_of_refrigerator.jpg"}}" alt="" />
-
07/28/2022
How to install a Vane Pump
The pump body is installed and fixed on a special foot rest with screws, and the foot rest is fixed on the base plate of the machine and equipment with bolts.
-
06/21/2022
What is a Transformer?
A transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.
-
09/06/2020
What should I do if the bearing is broken
How to judge whether the bearing can be used again and the defect that needs to be replaced To judge whether the bearing can be used again, it should be decided according to related factors such as bearing damage level, mechanical performance, importance, operating conditions, inspection period, etc.
-
09/05/2020
What are the effects of the failure of the internal parts of the screw air compressor on the equipment
How can I quickly diagnose the cause of an air compressor failure? I think only by having a good understanding of the internal structure of the air compressor and understanding the functions and functions of each accessory can we find the cause of the failure in time.
-
07/09/2020
Global Oil Free Compressor (Oil-Free Compressor Oil-Free Air Compressor) Market 2020 – Atlas Copco, Ingersoll Rand, Sullair
World Oil Free Compressor (Oil-Free Compressor Oil-Free Air Compressor) Industry Research Report 2018 – Global Market Perspective, Industry Intelligence, Size, Share, Growth, Trends and Forecasts Up to 2025
-
07/05/2020
Hitachi screw compressor failure case
Hitachi screw compressor failure case The author summarizes the case of Hitachi screw compressor maintenance and replacement bearings, and shares the data, please send it to a friend to collect and forward it for use
-
08/14/2020
How to select the cooling fan in the floor heating and air conditioning system
For many dealers in the north, the heating end may be familiar, but they are not very confident in the cooling end. In our WeChat group, dealers often consult related questions.
-
08/24/2020
No compensation for fire damage caused by air conditioner failure for more than 10 years
In January 2020, the Shanghai No. 1 Intermediate People's Court rejected the appeals of Shen and Sheng: The quality of the air conditioner caused the fire and the loss, and Sharp should bear the corresponding compensation responsibility.