08/16/2020
Can the chiller use a descaling agent for descaling
In fact, the use of a descaling agent for descaling is a common practice for the descaling work of the chiller. Therefore, the chiller can completely use the descaling agent for descaling. This is not a problem.
-
06/30/2020
Common faults and causes of compressors
Common faults and causes of compressors Common compressor failures are as follows: L. The compressor cannot start normally The power supply voltage is too low, the motor circuit is poorly connected, or the exhaust valve is leaking, resulting in too high pressure in the crankcase. The energy regulation mechanism has failed.
-
08/31/2022
Top 3 Things you must Know about Circuit Breaker
The circuit breaker is a very common safety component in the circuit. It can break the circuit at the proper time to protect the circuit and other equipment. To better learn about how it works, we’d better figure out some key concepts.
-
04/30/2022
How to Judge The Model of AC Contactor?
Contactor is the most basic and common electrical component in relay control system. It is mainly used to connect and disconnect lines, or frequently control the operation of motors and other equipment.
-
06/25/2020
How to solve if the air conditioner is not cooling
If it is not in the cooling state, we can adjust it to the cooling mode; if the dust accumulation of the air conditioner severely reduces the cooling function, we can find professional personnel to disassemble the evaporator, fan blade, and filter. Completely clean up; if it is because no refrigerant is added, then we can add refrigerant.
-
03/21/2023
The Operation and Maintenance of Vacuum Pump
About 20 minute’s operation should be done in advance before vacuum pump starts to vacuumize assembling unit. And after oil temperature rises, open extraction valve of assembling unit to extract unit.
-
02/15/2024
My Furnace is Blowing Cold Air: 8 Reasons & Ways to Fix
During the cold months, a furnace is your best friend, providing the warmth needed to keep your home comfortable. However, discovering that your furnace is blowing cold air can be disconcerting.
-
01/15/2021
Danfoss extends its Turbocor® training and support resources with 12 new e-lessons
Danfoss has released new online training materials for technicians working with its Turbocor® oil-free compressors—further extending the support and learning resources to help users and OEMs maintain long-lasting performance.
-
08/16/2020
What factors will cause the cooling performance of water-cooled chillers to decline
Water-cooled chillers are especially suitable for places with abundant water resources. The operation is more stable. It has the characteristics of large single-unit cooling capacity and high cooling efficiency.
-
06/14/2020
Do summer air-conditioning rooms need air purifiers
Do summer air-conditioning rooms need air purifiers It is high temperature in summer again. Many people have disputes about whether an air purifier is needed in summer.