Connection Solder ODF ×ODF in.¾ mm 19
Min. OPD Δp [bar] 0.02
Kv [m3/h] 4.2
Cv [gal/min] 4.86
Max. working pressure [bar] 45
Max.back‐wards di.pressure (4)[bar] 45
Multi pack[Pcs. per pack] 28
For R134a, R22, R407C, R404A refrigerants.
DANFOSS Check Valve CCV19S
People who bought this item also viewed
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ANV Switch LS-7144
Recent related posts
-
06/23/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/12/2020
Causes and troubleshooting of refrigeration solenoid valve failure
The refrigeration solenoid valve is an industrial equipment controlled by electromagnetic, used in the industrial control system to adjust the direction, flow, speed and other parameters of the medium.
-
09/19/2022
Top Circuit Breaker Brands
Circuit breakers are switching appliances that provide circuit overload and short-circuit protection.
-
06/22/2020
How often does the freezer cool
It is normal for the freezer to cool once every 10-20 minutes. The cooling time of the freezer is not fixed, it is related to the set temperature, usage, storage items and service life. If it's a new refrigerator you just bought, you set it to 4th gear cooling, you may have to wait a few hours before cooling, this is because the new refrigerator is synchronized with the room temperature, cooling requires a process. <img src="{{media url="magefan_blog/How_often_does_the_freezer_cool.jpg"}}" alt="" />
-
08/08/2020
Reasons for condensation at the bottom of the condenser
Reasons for condensation at the bottom of the condenser 1. It is abnormal if condensation occurs at the bottom of the condenser when the unit is running. It may be the reason for the low amount of refrigerant.
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,
-
09/10/2020
What problems should be paid attention to when operating the centrifugal oxygen compressor
Compared with air compressors, centrifugal oxygen compressors are characterized by their different working media. Oxygen is a strong oxidizer and combustion-supporting agent. Therefore, there are stricter requirements for safety in design, manufacturing, installation, and use management. E.g:
-
06/14/2020
Refrigeration compressor technology development trend
The refrigeration compressor is the "heart" of the refrigeration system, and its thermal performance and reliability largely determine the thermal performance and reliability of the refrigeration system. In order to meet the needs of users and fierce mark ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
09/06/2020
Application of High Pressure Soft Start on Compressor Load
Abstract: The high-voltage and high-power motor has a relatively large impact on the load and the power grid when starting. Thyristor series high-voltage soft starters are widely used for their superior starting performance and other advantages.
-
07/27/2020
Analysis of car air conditioning system
The inside of the car air conditioning system is where bacteria and mold accumulate. Mold will be