There is no price at present, you can Request a Quote
Series | AUB Series |
Fan Type | Axial Fan |
Size / Dimension | 80 mm SQUARE |
Bearing Type | Superflo |
Voltage - Rated | 12 VDC |
Air Flow | 63.54 CFM |
Noise | 47.5dB(A) |
Power (Watts) | 5.04 W |
Speed (RPM) | 5400 RPM |
Termination | 2 Wire Leads |
Weight | 73g (2.57 oz) |
Delta Fan AUB0812VHD
There is no price at present, you can Request a Quote
People who bought this item also viewed
CROWN Fan AGE06015B24H
Ebmpapst Fan A2D250-AJ02-11
Delta Fan AFB1212HHE-R00
Delta Fan FFB0424VHN-TZT4
Delta Fan KFB0505HHA
Delta Fan EFB1324SHE-4C58
Ebmpapst Fan 4412M
Nidec Fan D04G-05TS1
SUNON Fan GB1205PKV3-8AY
IKURA Fan UN7556M-GT-TP
Hitachi Compressor SD122SW-H3AG
Kinco VFD Frequency Converter SV100-2T-0150G
OMRON Power Supply S8JC-Z05005C
TOGI Transformer TRH1K-41S
Siemens Contactor 3RT2535-1AL20
Oriental Motor Electric Motor PK299-03A
Danfoss Sight Glass SG3S
Fanuc I/O Module A03B-0815-C003
TYCO Relay KU93-4106-1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Servo Motor MSMA202S1G
Baumer Sensor IFRM 06P3701/PL/0500
CHELIC Air Cylinder JE50*400-B
Recent related posts
-
08/24/2020
No compensation for fire damage caused by air conditioner failure for more than 10 years
In January 2020, the Shanghai No. 1 Intermediate People's Court rejected the appeals of Shen and Sheng: The quality of the air conditioner caused the fire and the loss, and Sharp should bear the corresponding compensation responsibility.
-
08/07/2020
What is the temperature control range of industrial chillers and how to set the temperature
Industrial chillers are commonly used refrigeration equipment in the industrial refrigeration industry. They are characterized by a wide range of types, complete models, affordable prices, special customization, and a wide range of applications.
-
12/05/2022
Top 7 Linear Guideway Brands
The linear guideway, also known as the linear guide, is used for high-precision or high-speed linear reciprocating motion.
-
01/16/2021
Refrigeration compressor purchase
Compressor selection is the first step in the establishment of a refrigeration system. Choosing a suitable refrigeration compressor can neither have excess power nor insufficient cooling capacity, which can lead to an increase in power consumption. It mus 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱
-
09/16/2020
Air compressor sharing air storage method
When multiple pneumatic tools are used at the same time, multiple air compressors need to be used for combined air supply. In order to reduce the pulsation of the air supply pressure and prevent the air pressure from falling instantaneously when multiple pneumatic tools are started at the same time on the working surface
-
08/19/2020
Why does refrigerating oil deteriorate How to judge whether the refrigerant oil has deteriorated
How to choose refrigerating oil 1.Why does refrigerating oil deteriorate? First of all, we must be clear why the refrigeration oil deteriorates.
-
08/02/2020
Characteristics of R12, R22, R407C refrigerants in cold storage
don’t know if you still remember that okmarts.com wrote "How to Choose Refrigerant for Cold Storage Design" some time ago. Today okmarts.com will introduce several different cold storage refrigerants in detail, namely R12, R22, R407C
-
09/14/2020
Application of oil bath air filter in air compressor industry
Cement plants have many production and grinding processes, and the ambient air contains high dust concentrations. The original design of dust removal filter device used in air compressor is mostly paper filter element dust removal.
-
06/23/2022
What is an Encoder?
An encoder is a communication device that controls the motion of an operating device. Encoders can help determine the speed or position of a motor, or other moving equipment.
-
07/31/2020
How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage.