Series | FFB Series |
Fan Type | Axial Fan |
Features | Locked Rotor Protection |
Size / Dimension | Square - 127mm L x 127mm H |
Width | 38.00mm |
Bearing Type | Ball |
Voltage - Rated | 24 VDC |
Static Pressure | 0.799 in H2O (199.0 Pa) |
Air Flow | 200.0 CFM (5.60m³/min) |
Noise | 59.5dB(A) |
Power (Watts) | 28.8 W |
Speed (RPM) | 3850 RPM |
Termination | 2 Wire Leads |
Operating Temperature | 14 ~ 158°F (-10 ~ 70°C) |
Approval Agency | CE, CSA, UL, VDE |
Weight | 1.1 lbs (499.0 g) |
Delta Fan FFB1324EHE
People who bought this item also viewed
IKURA Fan THC1B-18F5-TP-0T2-CMM570
EVERFLOW Fan T127010BU
Ebmpapst Fan W2D250-EA26-21
Delta Fan AHB1548GHG-F06
Delta Fan NS85B01-17A02
Delta Fan NC55C02-15K14
Delta Fan EFB0624HHA
Delta Fan EFB1324SHE-4C58
SUNON Fan HA30101V3-0000-A99
Servo Fan CNDC24B7P
Sanyo Denki Fan 9WF0624H4D04
Danfoss Compressor GL60ADa
Rockwell Allen-Bradley AB VFD 20P41AB218RA0NNN
COSEL Power Supply LFA150F-24-SNR2Y
TRIAD Transformer VPP10-1000
Schneider Circuit Breaker A9F74250
Siemens Contactor 3RT1054-2NB36
Danfoss Sight Glass SGI22S
IDEC Input Output Module FC6A-L06A1
FUJITSU Relay FTR-B4SA4.5Z
ABB Capacitor CLMD53-35KVAR 440V 50Hz
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Sensor EE-SX952P-R
Siemens Transmitter 7ML5670-0BB00-0AB0-Z
Danfoss Transmitter 064G0910
Recent related posts
-
06/14/2020
Global Refrigeration Compressor market
Global Refrigeration Compressor market by Type: Reciprocating Compressor, Rotary Compressor, Screw Compressor, Other Global Refrigeration Compressor market by application: Domestic, Small commercial, Commercial, Industrial
-
06/14/2020
Ammonia refrigeration equipment has leaked, which is the safest way to deal with it!
Ammonia refrigeration equipment has leaked, which is the safest way to deal with it! 1. The danger of ammonia refrigeration system in advance According to the statistical analysis of the actual operation of the refrigeration system, the safety risk ma 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢
-
08/20/2020
Introduction and characteristics of several throttling devices in refrigeration equipment
Among the four major components in the refrigeration system, the throttling device is one, and its function makes it have its own role.
-
08/03/2020
The difference between refrigerant R404A and R507
Refrigerant is also called refrigeration working fluid, which is the blood of refrigeration system. It is called refrigerant, refrigerant or Freon in many places.
-
08/02/2020
New refrigerant R450A is used for performance study of ejector refrigeration cycle
The new refrigerant R450A is a substitute for R134a, which is environmentally friendly and reliable. There are still few studies on it.
-
04/30/2022
How to Judge The Model of AC Contactor?
Contactor is the most basic and common electrical component in relay control system. It is mainly used to connect and disconnect lines, or frequently control the operation of motors and other equipment.
-
01/27/2023
What is a Smart Pressure Transmitter?
The definition of a smart pressure transmitter is arguable. Some people think that smart pressure transmitters refer to those with highway addressable remote transducer (HART) protocol output
-
08/05/2020
How to solve the problem of too high compression ratio of chiller
In the process of using industrial chillers, various problems will inevitably occur. Due to the structure of the industrial chiller, once the compression ratio of the compressor is too high, it will affect the working efficiency of the industrial chiller.
-
06/30/2020
Broken suction valve of Bristol compressor
Broken suction valve of Bristol compressor A Bristol compressor is a machine that compresses gas. Generally, the piston compresses gas 1450 times per minute (half-sealed compressor) or 2900 times (full-sealed compressor), that is, the time to complete an intake or exhaust process is 0.02 seconds or even shorter.
-
08/29/2020
How to achieve zero failure of enterprise compressor equipment
How to achieve zero failure of enterprise compressor equipment