Dungs Combustion Controller VPM-VC V1.1
People who bought this item also viewed
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
NORGREN Air Cylinder RA/8040/150
Balluff Sensor BOS01FT
PANASONIC Capacitor 400V 1000UF
NORGREN Air Cylinder M/146032/M/200
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Recent related posts
-
09/05/2020
What is the two-stage compression permanent magnet frequency conversion
Domestic sales of energy-saving air compressors are in full swing. Permanent magnet variable frequency air compressors and two-stage compression permanent magnet variable frequency air compressors are representative of energy-saving air compressors and are currently the mainstream products on the scene.
-
06/25/2020
Advantages and disadvantages of Hitachi central air conditioning
At present, the central air-conditioning of the refrigerant system is still the best done by Japanese brands. When it comes to Japanese central air-conditioning, one has to say that Hitachi, one of the Japanese air-conditioning BOSS, is a well-known international central air-conditioning brand. Most air conditioners now use scroll compressors as the core of power, and the world’s first scroll machine for air conditioning was manufactured by Hitachi in 1983.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/23/2020
Analysis of Overheating Failure of Refrigeration Compressor
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>
-
11/23/2023
How to Keep Your Computer Cool (Desktop, Laptop, or Computer CPU Temperature is too High)
The main sources of heat in a computer are the processor (CPU) and graphics processing unit (GPU). When these components work, they generate a lot of heat.
-
08/26/2020
Features of scroll refrigeration compressor:
Advantages of scroll refrigeration compressors:<br></br> 1. There is no reciprocating mechanism, so the structure is simple, small in size, light in weight, few parts (especially few wearing parts), and high reliability;<br></br>
-
09/05/2020
What are the main functions and functions of air compressor post-processing equipment
What are the main functions and functions of air compressor post-processing equipment? In an air compressor system, in addition to an air compressor to produce compressed air, post-processing equipment is also required to cool, dry and purify the air.
-
08/09/2023
Why is My Heat Pump Icing Up? Understanding the Causes and Solutions
Heat pumps are an essential household appliance that is used to regulate room temperature all year round. They are designed to extract heat from the ground or air outside and transfer it inside the home to keep it warm during the winter and cool during the summer.
-
03/21/2022
How to Replace a Circuit Breaker?
A circuit breaker is a switching device connected to an electrical circuit that interrupts the current flow when it is excessive.
-
08/15/2020
The main cause of cold storage fire is cold storage installation or cold storage construction
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.