Global one-stop procurement platform for industrial spare parts.
support01@okmarts.com service@okmarts.com hydraulic@okmarts.com
Okmarts.com Online Store, Refrigeration Compressor Price, O&Kmarts Logo
Max 200 characters
Display the website inEN
EN
translate to EN
EN
translate to ES
ES
translate to العربية
العربية
All
Omega
Omega
  • Flowmeter
    Flowmeter
  • Temperature Controller
    Temperature Controller
SIARGO
SIARGO
  • Flowmeter
    Flowmeter
SHINAGAWA
SHINAGAWA
  • Flowmeter
    Flowmeter
SEBA
SEBA
  • Flowmeter
    Flowmeter
RYUKI
RYUKI
  • Flowmeter
    Flowmeter
Rosemount
Rosemount
  • Transmitter
    Transmitter
  • Flowmeter
    Flowmeter
All Brands
All Brands
    • a
    • b
    • c
    • d
    • e
    • f
    • g
    • h
    • i
    • j
    • k
    • l
    • m
    • n
    • o
    • p
    • q
    • r
    • s
    • t
    • u
    • v
    • w
    • x
    • y
    • z
    • 3
    • 7
      Top Picks
      • Dwyer Flowmeter VFA-25-SS
      1/1
      Dwyer Flowmeter VFA-25-SS

      There is no price at present, you can Request a Quote

      • Specifications
      • Q&A
      • Reviews
      Service:Compatible gases and liquids.
      Wetted Materials:Body: Acrylic plastic; O-ring: Buna-N (fluoroelastomer available); Metal parts: Nickel plated brass standard, SS optional; Float: SS, black glass, aluminum, K monel depending on range.
      Temperature & Pressure Limits:Without Valve: 100 psig (6.9 bar) @ 150°F (65°C); 150 psig (10 bar) @ 100°F (38°C); With Valve: 100 psig (6.9 bar) @ 120°F (48°C).
      Accuracy:VFA = 5% of FS; VFB = 3% of FS.
      Process Connection:1/8" female NPT. VFB ranges 85 and 86 have 1/4" NPT back connections or 3/8" NPT end connections. These ranges not available with brass valves.
      Scale Length:VFA 2" typical length; VFB 4" typical length.
      Mounting Orientation:Mount in vertical position.
      Weight:VFA: 4.0 to 4.8 oz (.11 to .14 kg)

      Ask questions

      (0/1,200)

      Max 1200 characters

      • Q: Can I request a specific delivery date for my order?

        A: While we strive to deliver orders promptly, specific delivery date requests may not always be possible due to logistics and carrier limitations. However, if you have a specific requirement or need expedited shipping, please contact our customer service, and we will do our best to assist you.

      • Q: What should I do if I forgot my password?

        A: If you forgot your password, click on the "Forgot Password" link on the login page. Follow the instructions to reset your password.

      • Q: Do you offer free shipping?

        A: We may offer free shipping on select products or as part of promotional campaigns. You can check the product details or promotions to see if free shipping is available.

      View More
      Question has been sent successfully

      Reviews

      • A

        Anonymous user

        Nov 25, 2022

        Dwyer Flowmeter VFA-25-SS
        All was ok! No problems whatsoever.
        Helpful
        Unhelpful

      Dwyer Flowmeter VFA-25-SS

      There is no price at present, you can Request a Quote

      People who bought this item also viewed

      New In stock for sale, SUNTEX Turbidity Meter TC-7100

      SUNTEX Turbidity Meter TC-7100

      US$8392.31

      Customers frequently viewed

      New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

      IWAYA DENKI Water Pump 25CJT0752

      US$2307.69
      New In stock for sale, Panasonic Servo Motor MHMF022L1V2M

      Panasonic Servo Motor MHMF022L1V2M

      US$653.85
      New In stock for sale, Honeywell Solenoid Valve VE4025B1045

      Honeywell Solenoid Valve VE4025B1045

      US$334.62
      New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

      ROTEN Mechanical Seal 8E5K-22-X

      US$384.62
      New In stock for sale, SANDSUN Overload Pump VA08H-760

      SANDSUN Overload Pump VA08H-760

      US$1568.40
      New In stock for sale, GS Battery 6-QW-60(450)-(55D23L-KR)

      GS Battery 6-QW-60(450)-(55D23L-KR)

      US$646.15
      New In stock for sale, Rechi Compressor 44R273A

      Rechi Compressor 44R273A

      US$341.00
      New In stock for sale, Bosch Rexroth Linear Guideway Runner Block R165381920

      Bosch Rexroth Linear Guideway Runner Block R165381920

      US$107.69
      New In stock for sale, MINDMAN Air Cylinder MCQV2-11-40-200

      MINDMAN Air Cylinder MCQV2-11-40-200

      US$88.46
      New In stock for sale, Mitsubishi Compressor YB645WTG

      Mitsubishi Compressor YB645WTG

      US$549.00
      New In stock for sale, Servo Fan SCBD12B4-998

      Servo Fan SCBD12B4-998

      US$63.85
      New In stock for sale, Yaskawa Servo Motor SGMAH-08A1F-YA11

      Yaskawa Servo Motor SGMAH-08A1F-YA11

      US$1129.23
      New In stock for sale, Leuze Sensor PRK3C.A3/4P

      Leuze Sensor PRK3C.A3/4P

      Contact Us
      New In stock for sale, HIGH-TECH Vane Pump PV2R23-26-52-F-1R-UU-10

      HIGH-TECH Vane Pump PV2R23-26-52-F-1R-UU-10

      US$1000.00
      New In stock for sale, ULVAC Vacuum Pump PMB2400DT-MF2A1S7I2XX

      ULVAC Vacuum Pump PMB2400DT-MF2A1S7I2XX

      Contact Us
      New In stock for sale, ISCAR Tool for Metal Cutting DGL2000P-15D IC508

      ISCAR Tool for Metal Cutting DGL2000P-15D IC508

      US$21.25
      New In stock for sale, Copeland Compressor 6DHNR35ME-TSK-800

      Copeland Compressor 6DHNR35ME-TSK-800

      Contact Us
      New In stock for sale, CHELIC Air Cylinder RTB-3

      CHELIC Air Cylinder RTB-3

      Contact Us
      New In stock for sale, TOYOOKI Vane Pump HVP-FEE1-F120-120L-A-G

      TOYOOKI Vane Pump HVP-FEE1-F120-120L-A-G

      Contact Us
      New In stock for sale, AirTAC Air Cylinder ACP63X175

      AirTAC Air Cylinder ACP63X175

      US$96.92

      Recent related posts

      AC Compressor Bearing - Working Principle & Troubleshooting

      09/04/2025

      AC Compressor Bearing - Working Principle & Troubleshooting

      Bearings play an irreplaceable role in mechanical design. They involve very wide applications.

      How to Measure Air Pressure in A Cylinder?

      05/18/2022

      How to Measure Air Pressure in A Cylinder?

      During use, the cylinder piston bank will deteriorate due to wearing, ablation, gumming, carbon deposition and other reasons.

      Ethylene plant training materials

      09/10/2020

      Ethylene plant training materials

      Chapter One  Typical Process of Ethylene Plant The first section   sequence separation process Section 2 Front deethane process Section 3 Front depropanization process Section 4 Low investment separation process Section 5 Progressive separation process Section 6 Oil absorption and separation process Section 7 Comparison of six separation processes

      How to Test a Mass Flow Sensor?

      09/07/2021

      How to Test a Mass Flow Sensor?

      The mass flow sensor, or air flow sensor is one of the important sensors of the electronic fuel injection engine.

      What is the relationship between cold storage safety and cold storage board selection

      08/19/2020

      What is the relationship between cold storage safety and cold storage board selection

      The choice of insulation materials in the refrigeration system is also very important to the safety of the entire refrigeration system. In fact, the main difference between polystyrene board and polyurethane board is the heat preservation effect, price, technology and material.

      Introduction to the principle and characteristics of cold storage lights

      08/16/2020

      Introduction to the principle and characteristics of cold storage lights

      As a necessary facility for cold storage, cold storage lights are indispensable for every cold storage. So how to choose the cold storage lamp? Is general lighting okay? What is the difference between professional cold storage lamps and ordinary lighting lamps?

      What are the causes of air conditioning trip

      06/20/2020

      What are the causes of air conditioning trip

      What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

      How to clean the air cooler

      06/19/2025

      How to clean the air cooler

      Today, the editor of okmarts.com will give you a brief introduction to the cleaning method of the air cooler. I hope it will be helpful to you!

      Something You Need to Know about Using the Car AC after Stop

      08/06/2021

      Something You Need to Know about Using the Car AC after Stop

      In summer, many people like to park their cars on the side of the road, opening the air conditioner for a long time.

      Do you know all the protective devices for air-cooled chiller refrigeration compressors

      08/05/2020

      Do you know all the protective devices for air-cooled chiller refrigeration compressors

      In order to prevent the air-cooled chiller from running uninterruptedly for 24 hours, causing the compressor to operate under high load, the electromagnetic switch is not good, the overcurrent caused by the shaft holding,

      • Welcome to O&Kmarts

        Is there anything we can help?

        Email us
      • Feedback

      Join in

      Join in to enjoy exclusive discounts and give you greater discounts

      See More About O&Kmarts Member
      Sign up now

      Common Problem

      Payment Methods
      Shipping Guide
      Sales and Refund Policy
      FAQs

      About O&Kmarts

      About Us
      Membership

      Website Terms

      Privacy Policy
      Terms Of Use
      Bidding Agreement
      Review Rules

      Customer Service

      support01@okmarts.com
      service@okmarts.com
      hydraulic@okmarts.com
      +86-28-84166335
      GMT+08:00 Mon-Fri, 9:00 AM-7:00 PM
      Customer Feedback

      POPULAR PRODUCTS :

      FD-R50 AXFC-4-L010/CH AXFC-4-L015/CH AXFC-4-L010/CH AXFC-4-L015/CH 25CJT0752 MHMF022L1V2M VE4025B1045 8E5K-22-X VA08H-760 2938604 Asco WBIS8316A302 CKD EXA-03-02HS-3 e40s6 500 3 t 24 Eaton Vickers KBFDG4V-3-2C20N-Z-PE7-H7-10 fuji sc 05 contactor kd1208ptb1 MAC 916B-PM-611JB mhmd082g1u Panasonic QA91K21CAW5 (CSIR) PHILIPS For Philips Shaver S5050 S5075 AT610 FT658 FT618 FT668 688 R4E355-RM03-05 Rexroth 4WE 6 J70/HG24N9K4 Rexroth 5610111000 RS199VHRC SNB172FEKMT SUN RDDT-QAN TACO 363-400-00B0 Togami CLK-28J yaskawa sgdv 120a01a

      Disclaimer: All brand names, model or type numbers or marks listed on the website are owned by their respective manufacturers. These terms are used for identification purposes only and are not intended to indicate affiliation with OEM companies. Product pictures shown on the website are for illustrative purposes only and the actual item may vary in design, specification, etc. Confirm at the time of purchase if you are unsure.

      © eCommerce. 2017-2025. All Rights Reserved
      © eCommerce. 2017-2025. All Rights Reserved
      Press and drag the mouse to start taking a screenshot