There is no price at present, you can Request a Quote
Series | VDC-11 Series |
Brand | EALY |
Pump Type | Variable Displacement-Double Vane Pump |
Adjustable Type | Addition |
Mounitng | Foot Mtg. |
Shaft End (c.c/rew) | 25 |
Shaft End Pressure Range | 50-105 kgf/cm² |
Cover End (c.c/rew) | 20 |
Cover End Pressure Range | 15-35 kgf/cm² |
Mass (Approx.) | 25.2 kg |
We can also provide the following models
PV2R12-19-53LRELB-40
50T-14LRL-PA-12-X
50T-14LRRX-10
PV2R12-25-38LLEBL-40
50T-40LRL-PB-19-X
150F-75LRR-10
VVPE-L12C-8B-9T
150F-125LRR-150T-125
150F-75LRR-50T-07
50T-23FRR-50T-40
50T-23FRR-50T-43
PV2R12-19-65FLERB-40
PV2R2-26FLBBX-10
VVPE-F15A-8B-10
50T-14FRL-PB-17
PV2R12-25-26LLERL-40
VDCG-2-A-F-70-C-PA-20
VDCG-2A-F-86-B-PA-20
50T-43FLL-PA-11-X
50T-43FLR-50T-43
PV2R12-25-38FLEBB-40
150T-48FRL-PV2R2-53
150F-116LLL-PV2R2-26
For more information,please contact us freely
Ealy Vane Pump VDC-11BL-25C-20A-20
There is no price at present, you can Request a Quote
People who bought this item also viewed
EALY Vane Pump VDC-1A-F20D-20
EALY Vane Pump VDC-2B-F54C-20
EALY Vane Pump VPE-F15D-10
EALY Vane Pump VDC-11A-F30D-30D-20
Yuci Vane Pump PFED-42070-006-1DT
Camel Vane Pump VCM-SF-30AS-20
Kompass Vane Pump VB1B1-24+24F-A2-A2
KEISTER Vane Pump PVL12-28-33-F-1R
KITZ Check Valve EN16FCO-DN65-2 Inch
DAIKIN Overflow Valve SGR-G06-1-10
NACHI Piston Pump PVD-2B-40P-16G5-4702F
HPI Gear Pump P2BAN2625
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
OPG Electric Motor 6IK180RA-CI
Siemens Contactor 3RT2516-1AP00
THK Linear Guideway HSR8RM2UU+95LPM
OMRON Relay G6K-2F-DC5
SMC Solenoid Valve VFR5310-5DZ-04
LIMING Electric Motor SV-A10
Recent related posts
-
08/20/2020
Installation and placement conditions of cooling tower of thermal shock tester
Let's learn about the installation and placement conditions of the cooling tower of the thermal shock tester with the editor of okmarts.com! 1. The ground is flat and well ventilated;
-
06/16/2022
What is A VFD?
A Variable Frequency Drive (VFD) is a type of motor controller that drives an electric motor by varying the frequency and voltage supplied to the electric motor.
-
06/14/2020
Description of refrigeration compressor maintenance methods
Description of refrigeration compressor maintenance methods This article mainly describes the related content of the maintenance methods of refrigeration compressors
-
09/05/2020
What role does air compressor play in washing equipment and how to use it safely
Generally, you need to buy an air compressor to open a laundry room, so how big an air compressor should be configured in a general laundry room? This is the concern of the owner of the investment laundry room
-
07/18/2020
reasons why the constant temperature and humidity test chamber does not cool
1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil damage the suction valve plate when the gas is sucked into the cylinder of the compressor, and it is produced when the piston is compressed when the piston is close to the top dead center and is not quickly discharged during the exhaust process after entering the cylinder.
-
08/16/2020
What are the reasons for the shortened life of cold storage projects
With the progress of society and the development of all walks of life, the installation of large and small cold storage has gradually risen and spread quickly across the country.
-
08/20/2020
How to judge the fault based on the indicator light of the ice machine
1. The power indicator light keeps flashing quickly and the machine does not work: The cause of the failure: the water temperature probe is open. Repair method: Open the rear cover, open the cover of the electric control box above the compressor, find a three-core connector, check if there is any dropout or poor contact, then reconnect it.
-
07/05/2020
Hitachi heat pump compressor
Does the compressor not start related to the four-way valve? There is no relationship between the compressor does not start and the four-way valve. Therefore, when the four-way valve coil is damaged, it will not cause the air-conditioning compressor to fail to start normally, nor will the compressor start normally after the good four-way valve coil is replaced.
-
08/05/2020
Can you judge whether the refrigeration compressor is leaking in 5 steps
Insert the power plug of the air conditioner into the power source, and the air switch will trip immediately! Compressor leakage? Follow the following five steps to confirm the compressor leakage fault.
-
11/28/2023
Step-by-Step Guide on How to Clean a Desktop PC from Dust with Figures
Dust is the biggest culprit affecting the life of desktop computer hardware! Generally speaking, the dust in a computer tower needs to be cleaned regularly.