Part Number | - |
Seal | Nitrile Seals |
Pump Type | Single Vane Pumps |
Series | V10 Series |
Cover Type | Standard cover |
Mounting | Flange, 2 bolt SAE A size |
Inlet Port Connection | 1" NPT thread |
Rated Capacity | 26.5 l/min (7 USgpm) |
Outlet Port Connections | 1" NPT thread |
Shafts | Straight, keyed |
Pressure port positions | In line with inlet |
Rotation | Right hand (clockwise) |
Geometric Displacement,cm ³ /r (in ³ /r) | 22.8 (1.39) |
Maximum Pressure,bar (psi) | 138 (2000) |
Maximum Speed | 2800 rpm |
Minimum Speed | 650 rpm |
Weight | 4.5 - 6.8 kg (10 - 15 lb) |
Eaton Vickers Vane Pump V10-1P7P-1C20
People who bought this item also viewed
YUKEN Vane Pump PV2R12-19-65-L-REAA-41
OUYIPU Vane Pump IVP-30C-10
YUKEN Vane Pump PV2R3-76-L-RAA-31
KEISTER Vane Pump PV2R2-59-FR
Eaton Vickers Vane Pump 4525V-42A10-1AA22R
Eaton Vickers Vane Pump V20-1P13P-1C11
Eaton Vickers Vane Pump 35V-38A-1C22R
Eaton Vickers Vane Pump V20-1B9B-1A11
Camel Vane Pump VCM-SF-30C-10
ANSON Vane Pump PVF-30-35-10-S
Rexroth Vane Pump PVV4-1X-098RA15DMC
Yuci Vane Pump PFED-42029-012-1DT
SUN Check Valve CKIB-LCN
OMAX Overflow Valve SPRV-10G
Rexroth Piston Pump A4VSO180EO2/30R-PZB25N00
HYTEK Gear Pump HG10-63-63-01R-VPC
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder MAC25X120-S-CM
Sanyo Denki Fan 9GA0924P4S031
NVICKS Vane Pump 4525VQ75A14-1CC20R
Yaskawa Servo Drive SGDM-50AD-HQ1A
Recent related posts
-
12/19/2022
What is an Optical Fiber Amplifier?
The optical fiber amplifier, also known as the optical fiber ampler (OFA for short), refers to a new type of all-optical amplifier used in optical communication link to realize signal amplification.
-
06/13/2020
Common air conditioning host
Common air conditioning host 1. Water-cooled chiller The water-cooled chiller belongs to the refrigeration unit part in the central air-conditioning system. Its refrigerant is water, which is called the chiller, and the cooling of the condenser is r 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ
-
08/12/2021
How to Test a Refrigerator Compressor?
Refrigerators are very common in our daily life. Most people know how to use refrigerators, but they do not know the relevant knowledge.
-
08/14/2020
The reason why the fan of air-cooled chiller does not run
In many areas where water sources are lacking, or air-cooled chillers for cooling and cooling of supporting machinery and equipment, after several years of use, such and other small failures may occur.
-
08/05/2020
How to solve the common old problems in the operation of chillers
In the pharmaceutical, food, chemical and other industries, process water cooling is required. The chiller has become a must-choice equipment for many industries.
-
08/04/2020
Popular Science What is the difference between the cooling and dehumidification modes of air conditioners
It is raining in many places across the country, and the air conditioner, as a must-have item for people to enter the summer, is self-evident. Today's air conditioners have very powerful functions.
-
08/13/2020
8 simple maintenance common sense of combined cold storage you must understand
We will inevitably have some small failures in the process of using the cold storage. If we can do a little simple troubleshooting, we can eliminate the failures in the shortest time and reduce losses.
-
06/13/2020
Do you know question and answer with refrigeration compressors?
1. Why control the impurity content and moisture content of the compressor and air conditioning system?
-
06/22/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/28/2020
Why should you use a real oil-free air compressor
There have been a lot of discussions and reports on the issue of oil in compressed air. Some people believe that for some processes and final products, the air used can contain a certain amount of oil,