There is no price at present, you can Request a Quote
Type | EC Centrifugal fans |
Nominal voltage range | 3~380-480 V AC, 50/60 Hz |
Nominal voltage | 400 |
Speed n | 2480 |
Max. Input power | 2775 |
Max. Input current | 4.26 |
Sound power level LwA | 99 |
Perm. ambient temp. | -40..+45 |
Ebmpapst Fan R3G450PA3103
There is no price at present, you can Request a Quote
People who bought this item also viewed
ADDA Fan AD0412HB-J93
Ebmpapst Fan R2E175-AC77-21
CROWN Fan AGE06015B24H
Ebmpapst Fan W1G200-EA91-70
Ebmpapst Fan 4606ZWU-879
Ebmpapst Fan 4412FM
Ebmpapst Fan QG030-353/14
Ziehl Abegg Fan FB063-6EK.4I.V4L
SUNON Fan PMD2406PMB3-A
Sanyo Denki Fan 109L5724H501
Sanyo Denki Fan 109P0612W601
Danfoss Compressor MT44JE4CVE
AZBIL Transformer S720A100-GHA
Delixi Contactor CJX2S-3210
DKM Electric Motor 9IDGK-200F2P
Donaldson Filter P550345
Danfoss Sight Glass SGH 10S
Beckhoff Coupling Module EK1561
HONGFA Relay HF115F-T-012-1HS3A
MURATA Capacitor 16V 0.47UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder SCG-00-40B-35
SOG Oil Seal TC45*54*4.5
Bristol Compressor H82J22BABCA
Nader Contactor NDC1-9511
Recent related posts
-
09/14/2020
What is an air compressor
The machine used to generate compressed air is also called compressed air machine, also called air compressor, or air compressor for short. The motor directly drives the compressor to make the crankshaft produce rotational movement, drive the connecting rod to make the piston produce reciprocating motion, and cause the cylinder volume Variety.
-
03/02/2023
The Types of Air Cylinder and Notices for Use
Air cylinder is a tube-shaped metal mechanical part that guides the piston to do linear reciprocating motion in its insides.
-
07/18/2020
How to protect the refrigeration compressor
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
06/27/2020
The sign of the normal operation of the refrigeration unit
The sign of the normal operation of the refrigeration unit 1. There is no knocking sound in the piston refrigeration compressor, the compressor is operating normally, the expansion valve opening is adjusted properly, and there is only compressor suction and exhaust sound during operation, and no knocking or other abnormal sounds are produced.
-
06/29/2020
Causes of non-condensable gas in refrigeration system
Causes of non-condensable gas in refrigeration system 1. Insufficient emptying of the refrigeration system before charging the refrigerant Before charging the refrigerator, the compressor cylinder in the refrigeration system, the condenser, the evaporator, and the piping of the system were filled with air. In order to eliminate these air before charging the refrigerant, the interior of the refrigeration system Vacuuming,
-
08/20/2020
The role of pressure relay in refrigeration system
In industrial refrigeration, a pressure relay is an electric switch controlled by a pressure signal. It is often used as a protection and regulating element that directly controls the start and stop of the refrigeration compressor or controls the opening and closing of certain solenoid valves
-
09/08/2020
What are the functions of the air compressor dewatering device
The compressed air produced by the compressor is not pure. This is because the air compressor itself contains lubricating oil. During the compression work, part of the lubricating oil must be mixed into the compressed air.
-
08/29/2022
4 Common Types of Circuit Breakers
The circuit breaker is an automatic device for stopping the flow of current in an electric circuit as a safety measure.
-
09/06/2020
Application of synthetic compressor oil
At present, synthetic lubricants are widely used in the compressor field. Among them, oil-injected and oil-immersed rotary screw air compressors and large reciprocating compressors are one of the most used markets. For example, the sales volume of synthetic compressor oil in Western Europe was 6000t in the late 1980s, and it rose to 10000 in the early 1990s. The sales volume in the United States has exceeded 15,000 tons, and it is increasing at a rate of more than 10% per year.
-
08/13/2020
Why the air energy heat pump does not heat
It is a common phenomenon that air energy heat pumps do not produce heat. When air energy heat pumps were used in the winter of previous years, the water temperature would be insufficient.