There is no price at present, you can Request a Quote
VOLUMETRIC FLOW RATE:51m?/min
TOTAL PRESSURE DIFFERENCE:3800Pa
VOLTAGE:230/400V
FREQUENCY:60Hz
MOTOR RATING:2.64KW
Elektror Fan RD 7
There is no price at present, you can Request a Quote
People who bought this item also viewed
Ziehl Abegg Fan FN050-6EK.4F.V7P1
Y.S.TECH Fan FD488025HB
Sanyo Denki Fan 109P0912H201
Servo Fan E1540H24B7AZ-00
Sanyo Compressor C-RN223H3C
COSEL Power Supply CBS2002403-R
TRIAD Transformer FS20-1000
ABB Circuit Breaker E6H6300 T LSI 3P WHR
Schneider Contactor LC1D12EDC
Donaldson Filter P502424
Danfoss Sight Glass SGN19
SAWANA Relay SH3L 99999.9H
MALLORY Capacitor 23DD24SSA
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi Servo Drive MR-J2M-20DU-S020
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/06/2021
Parts of the Reciprocating Compressor
Parts of the Reciprocating Compressor Cylinder, Piston, Connecting Rod, Crankshaft: Parts of Reciprocating Compressor Introduction Now that we have seen the principle of working of the reciprocating compressor, let us see the various parts of the compr 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ
-
09/14/2020
Selection guide for air compressor
Selection of working pressure (exhaust pressure): When the user is preparing to purchase an air compressor, first determine the working pressure required by the air end, add a margin of 1-2 bar, and then select the pressure of the air compressor (the margin is considered from the air compressor The pressure loss from the installation site to the actual gas end pipeline distance, according to the length of the distance between 1-2 bar, appropriately consider the pressure margin)
-
06/30/2020
How to deal with the faulty host refrigerant system of the compressor
How to deal with the faulty host refrigerant system of the compressor How to deal with a main engine refrigerant system where the compressor has burnt out or failed is a more serious and technically demanding problem than the production of a new main engine. However, it is often neglected by most of the technicians, and even the wrong concept is replaced if they think that it is broken anyway! It causes some disputes that the compressor quality is poor or others use it improperly.
-
08/20/2020
Taboos for installing air conditioning and refrigeration pipes
Air-conditioning refrigeration pipes are used as auxiliary equipment in air-conditioning installation, but their importance cannot be ignored. If all relevant components have been
-
10/04/2023
Refrigerated Air Dryer: Everything You Need to Know
If you work in an industry that requires compressed air, you know that moisture is a common problem. When compressed air is cooled, it can condense, leading to water droplets that can damage equipment, cause corrosion, and affect the quality of the final product. That's where refrigerated air dryers come in.
-
02/21/2023
Classification of Butterfly Valve
Butterfly valve, which dated back in 1930s, is a common valve type. It is easy to be combined with various driving devices, with good durability and reliability.
-
09/16/2022
Hydraulic Pumps:Types and Pros & Cons
A hydraulic pump is the power component of the hydraulic system, which mainly plays the role of pressurizing the liquid, and is widely used in the metallurgical industry
-
06/13/2020
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
-
10/28/2021
Advantages of VFD for HVAC System
One of the most successful energy management tools ever used in HVAC (Heating, Ventilating and Air Conditioning) systems of buildings is the Variable Frequency Drive (VFD).