Max. permissible torque load Mx as a function of the stroke: 5.5 Nm
Stroke: 200 mm
Piston diameter: 40 mm
Type code: DFM
Drive unit operating mode: Yoke
Cushioning: Elastic cushioning rings/pads at both ends
Mounting position: Any
Guide: Sliding guide
Design: Guide
Position sensing: For proximity sensor
Symbol: 00991737
Operating pressure: 1.5 bar - 10 bar
Max. speed: 0.8 m/s
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 1 - Low corrosion stress
Ambient temperature: -20 to 80 Celsius Degree
Impact energy in the end positions: 0.7 J
Max. payload as a function of the stroke at defined distance xs: 127 N
Theoretical force at 6 bar, retracting: 686 N
Theoretical force at 6 bar, advancing: 754 N
Moving mass: 2411 g
Product weight: 5437 g
Alternative connections: See product drawing
Pneumatic connection: G1/8
Note on materials: RoHS-compliant
Cover material: Wrought aluminum alloy
Seals material: NBR
Housing material: Wrought aluminum alloy
Piston rod material: High-alloy stainless steel
Festo Air Cylinder DFM-40-200-P-A-GF
People who bought this item also viewed
Festo Air Cylinder DGP-32-600-PPV-A-B
KOGANEI Air Cylinder NHBRS-10
Festo Air Cylinder DSN-12-40-P
Festo Air Cylinder DSBC-50-125-PPVA-N3
Festo Air Cylinder AEVU-20-10-P-A
Festo Air Cylinder DPZJ-25-40-P-A-S2
Festo Air Cylinder DNC-32-400-PPV-A-KP
Festo Air Cylinder DSBC-40-320-PPSA-N3
CKD Air Cylinder SSD2-KL-50-75-N-W1
Festo Air Cylinder ADNGF-32-15-P-A
HENGSTLER Encoder RI58-O/1000ES.41KB
CKD Solenoid Valve 4KB249-00-DC24V
Johnson Controls Actuator VA-7200-1001
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-D/1000AE.47TB
SPG Electric Motor S9I90DB
ABB Circuit Breaker GSH203 AC-C25
Recent related posts
-
11/30/2021
Differences Between Sensor and Transmitter
Sensors and transmitters play an important role in the field of automatic control. Transmitters are developed based on sensors, which have close relationship and differences.
-
08/10/2020
How to choose refrigerant for high and low temperature alternating damp heat test chamber
There are many kinds of refrigeration used in the high and low temperature alternating damp heat test chamber, and different refrigerants have very different uses and application ranges. Today, we will focus on explaining the main refrigerants on the market.
-
06/14/2020
The reason for the frost on the compressor air inlet is here!
The reason for the frost on the compressor air inlet is here! Frost on the air inlet of the cold storage compressor is a very common phenomenon in the refrigeration system. Under normal circumstances
-
01/31/2023
What is a Gear Reducer?
The gear reducer is an independent enclosed transmission gear between the prime mover and the machine, which is used to reduce the speed and increase the torque to meet the work needs.
-
07/14/2020
Compressor 9 types of faults and hazard analysis are all here! ! !
Compressor 9 types of faults and hazard analysis are all here! ! ! 1. Common faults of compressor — start with liquid Starting with fluid is a problem that easily occurs when the machine is stopped. During shutdown, the refrigerant will migrate from the system back to the compressor and deposit in the lubricant.
-
01/05/2021
4 Common Refrigerator Compressor Problems You Need to Solve Fast
4 Common Refrigerator Compressor Problems You Need to Solve Fast A compressor is a vital part of the refrigerator, so it can be frustrating once breaks at inconvenient times. It’s not always easy to detect if the compressor has a problem, and it often ta 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
08/13/2020
How to apply the functions of cooling, heating, humidification, and dehumidification of computer room air conditioning
1. Uninterrupted operation and year-round refrigeration<br></br> The heat dissipation of the equipment in the computer room is a steady-state heat source, and it operates continuously throughout the year. This requires an uninterrupted air-conditioning gPﰨ2 䀀 湠癐
-
01/24/2024
Cooling Fans for Inverter Motors: Necessity, Intelligent Control and Selection Precautions
Since the inverter motor generates a large amount of heat when running, and poor heat dissipation will cause the motor temperature to be too high, thereby reducing the life and efficiency of the motor.
-
06/14/2020
Expansive survey of Global Air Compressor Market 2020
Manufacturing Healthcare Oil and gas development Besides, the report discusses the most integral market element, the competitive scenario