Piston diameter: 32 mm
Type code: DGC
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic shock absorber, soft characteristic curve: Pneumatic shock absorber, hard characteristic curve: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Guide: Recirculating ball bearing guide: Basic guide: Sliding guide
Position sensing: For proximity sensor
Variants: Axis clamping unit: Protected recirculating ball bearing guide: Additional slide, standard, left: Additional slide, standard on right
Operating pressure: 2 bar - 8 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb X
ATEX category for dust: II 3D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db X
Explosive ambient temperature: -10Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 1 (ATEX): Zone 22 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:-:-]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 1 - Low corrosion stress: 0 - No corrosion stress: 2 - Moderate corrosion stress
For use in the food industry: See supplementary material information
Ambient temperature: -10 to 60 Celsius Degree
Cushioning length: 17.5 mm
Theoretical force at 6 bar, retracting: 483 N
Theoretical force at 6 bar, advancing: 483 N
Alternative connections: See product drawing
Type of mounting: With accessories
Pneumatic port on clamping unit: M5
Note on materials: RoHS-compliant: Free of copper and PTFE
Cover material: Wrought aluminum alloy
Seals material: NBR: TPE-U(PU)
Festo Air Cylinder DGC-32-280-GF-YSR-A
People who bought this item also viewed
Compact Air Cylinder QJ92-1642-A
CHANTO Air Cylinder JUR25X15
Festo Air Cylinder DFM-32-125-P-A-GF
Festo Air Cylinder SLT-6-20-P-A
Festo Air Cylinder SLT-10-30-P-A
Festo Air Cylinder DNC-80-250-PPV-A-KP
TPC Air Cylinder NGQM16-50-TH
Festo Air Cylinder ADN-20-25-A-PPS-A
Festo Air Cylinder HGR-10-A
Festo Air Cylinder DSNU-20-60-P-A
Lika Encoder CK58-H-1024ZCU415
SMC Solenoid Valve SY5120-4DD-01
SIEMENS Actuator SAL61.03T10
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Contactor LC1N2510B6N
IRC Resistor 2W 29.6K
Recent related posts
-
08/20/2020
How to maximize energy saving of industrial chillers
1. Industrial water chillers prevent and reduce pipeline fouling to improve the heat exchange efficiency of condensers and evaporators. If water treatment is not done well, calcium
-
11/05/2021
10 Methods for VFD Troubleshooting
It is important to learn the helpful methods for VFD troubleshooting. In order to let everyone be capable of solving VFD problems, we have summarized 10 methods here.
-
09/17/2022
Classifications of Air Cylinders
The air cylinder, also known as the pneumatic cylinder, is a cylindrical metal part that makes the piston to perform a reciprocating motion.
-
07/26/2020
The influence of temperature on refrigeration compressor
In summer, the discharge temperature of the compressor is relatively high and cannot be touched by hands. According to national standards, the exhaust temperature of the R22 refrigeration system should not exceed 150 degrees Celsius.
-
12/28/2023
Troubleshooting a Heat Pump Fan Not Spinning (Outdoor Fan): Causes and Solutions
A heat pump is a reliable and energy-efficient HVAC system that provides both heating and cooling for your home. However, like any mechanical system, heat pumps can encounter issues from time to time.
-
09/11/2022
Servo Motor vs Stepper Motor: Comparison from 9 Aspects
Like servo motors, stepper motors are equipped with mechanisms that control the angle of rotation by receiving external signals.
-
05/30/2023
Why Does My AC Compressor Turn on and off Repeatedly?
Under the control of the thermostat, generally the air conditioner will stop working when it reaches the set temperature. For example, when the indoor temperature is 35 °C, you turn on the air conditioner and set it to cooling mode
-
08/12/2020
Causes and troubleshooting of refrigeration solenoid valve failure
The refrigeration solenoid valve is an industrial equipment controlled by electromagnetic, used in the industrial control system to adjust the direction, flow, speed and other parameters of the medium.
-
07/29/2020
Nine refrigerant leakage locations and solutions
There are many welds on the left and right sides of the evaporator, and there may be more leaks. The leak of the newly installed air conditioner is mainly due to the poor welding skills of the employees of the air conditioner manufacturer.
-
09/01/2022
Differences between a Contactor and a Relay
The contactor and the relay are all control devices used in electric circuit. But they cannot replace each other. The followings are the main differences between the two.