Stroke: 2 mm - 2000 mm
Piston diameter: 40 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Piston rod at one end: High corrosion protection: Special thread on piston rod: With end-position locking at both ends: Increased service life: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Low friction: Continuous, hollow piston rod: With rear end-position locking: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Heat-resistant seals max. 120Celsius Degree: Clamping unit on the piston rod: Constant, slow movement: Temperature range -40 to 80 Celsius Degree: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: With anti-twist protection: Extended piston rod: Dust protection: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: With front end-position locking: Internal thread on piston rod: Piston rod with external hexagon: Through piston rod: Extended external thread piston rod: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated
Protection against torsion/guide: Square piston rod
Operating pressure: 0.2 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 1 (ATEX): Zone 21 (ATEX): Zone 22 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 0.2 J
Max. torque for protection against rotation: 1.1 Nm
Theoretical force at 6 bar, retracting: 633 N
Theoretical force at 6 bar, advancing: 633 N - 754 N
Type of mounting: With internal thread: With accessories
Pneumatic connection: G1/4
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-40-90-PPV-A-KP
People who bought this item also viewed
Festo Air Cylinder DGP-32-600-PPV-A-B-KH-GK
CHANTO Air Cylinder MSR32X75
STNC Air Cylinder TGC80x50-S
Festo Air Cylinder DMML-20-30-P-A
Festo Air Cylinder ADNGF-12-10-P-A
Festo Air Cylinder AEVU-40-10-P-A
Festo Air Cylinder DNC-32-145-PPV-A
Festo Air Cylinder DGSL-10-40-P1A
Festo Air Cylinder DFM-16-30-P-A-GF
Festo Air Cylinder DPZJ-25-40-P-A-S2
MINDMAN Air Cylinder MCJS-12-80-35M
Autonics Rotary Encoder E40S6-1800-3-T-5
Belimo Actuator SRQ24A-SR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
YUKEN Overflow Valve LBS-16-V-7-D100-14
Renishaw Encoder RGH22R30D00A
Banner Light Curtain SLSP14-600Q8
CKD Air Cylinder STR2-B-20-25
TOWA SEIDEN Switch CA-B1SA-015
Recent related posts
-
07/19/2020
Advantages and disadvantages of screw refrigeration compressors
Screw refrigeration compressor is a rotary positive displacement compressor. It uses the change of the cogging volume and position of the screw to complete the process of vapor suction, compression and exhaust. Oil-free screw compressors came out in the 1930s, mainly used to compress air. Later, the oil-injected screw compressor appeared in the cylinder,
-
08/02/2020
Refrigerator refrigeration system leak detection
The refrigeration system should be tested for leaks due to refrigerant leakage or refrigerators after replacing parts. The following three methods are generally used for leak detection in refrigeration systems
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
11/28/2021
Photoelectric Encoder on CNC Machines Troubleshooting and Solutions
It is an automatic machine tool with program control system. The control system can logically process the programs with control codes or other symbolic instructions, decode them and express them with coded numbers.
-
02/07/2022
Why Refrigeration System Clogged
The blockages in the refrigeration system include ice, dust, oil and welding blockage, etc.
-
07/06/2020
Single Screw Compressor Market Trends, Opportunities, Drivers, Challenges And Porter’s Five Forces Analysis 2020-2026| Bosch, Sanyo (Panasonic), Atlas Copco AB, Ingersoll-Rand PLC, GE Oil & Gas, Gardner Denver, Inc.
LOS ANGELES, United States: QY Research offers an encyclopedic study of the global Single Screw Compressor market with holistic insights into vital factors and aspects that impact future market growth. The global Single Screw Compressor market has been analyzed for the forecast period 2020-2026 and historical period 2015-2020.
-
07/14/2020
What are the reasons why the air conditioner is not cooling?
What are the reasons why the air conditioner is not cooling? In summer, people turn on the air conditioner mainly to get a cool feeling, but they did not find that the air conditioner has not been cold for a long time. The air conditioner is not cooling. What are the reasons why the air conditioner is not cooling? Many air conditioners are not cooling, because it is faulty Problem, so it is necessary to repair it, what are the ways to repair the air conditioner?
-
06/30/2020
What are the factors that cause motor damage?
What are the factors that cause motor damage? What are the factors that cause damage to the compressor motor: 1. Abnormal load and stall
-
05/20/2022
5 Common Faults and Solutions of Air Cylinders?
Cause 1: The guide sleeve, rod seal ring or piston rod are worn. Solution 1: Replace it. Improve lubrication. Use guide rails.
-
06/24/2020
What is the problem with the poor cooling effect of the air conditioner
In the hot summer, I believe that many people can not do without air conditioning, air conditioning can allow us to spend this summer in a cool environment. However, in the process of using air conditioners, I believe that many people have encountered a situation where the cooling effect of the air conditioner is not good, so why is the cooling effect of the air conditioner not good? What needs to be solved.