Rated current: 6A
Pole number: 1
Fuji Circuit Breaker BC63E1DG-1P006
People who bought this item also viewed
GE Circuit Breaker SFKOG 1.6-2.5A
ABB Circuit Breaker GSH202 AC-C16
Fuji Circuit Breaker EW100EAG-3P063
Fuji Circuit Breaker EW32SBG-2P020
Fuji Circuit Breaker BW100EAG-2P075
Fuji Circuit Breaker CP30FM-1P001
Siemens Circuit Breaker 3RV1021-4AA10
Siemens Circuit Breaker 3RV2011-0EA10
Siemens Circuit Breaker 3RV1042-4EA10
Delixi Transformer JMB-700
Schneider Contactor LC1D1700F7C
Ferraz Shawmut Fuse PC72GB69V400TF
EATON Relay ZB32-32
UniOhm Resistor 1/8W0R-5%
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
WRS Diaphragm Pump MG0015 PVC
OKTY Oil Seal TC(FKM)190*220*15
PIZZATO Switch FA 4120-KSM
ABB Circuit Breaker 10061848
Recent related posts
-
06/14/2020
Cold storage equipment installation and commissioning
Installation of refrigeration compressor unit in cold storage: The condensing unit should avoid installing in high temperature environment, and the outdoor awning should be installed to avoid rain or direct sunlight. The air inlet side of the air-cooled c 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬
-
06/14/2020
What is the energy efficiency ratio of air conditioning
What is the energy efficiency ratio of air conditioning What does the air-conditioning energy efficiency ratio mean? How to calculate the air-conditioning energy efficiency ratio?
-
09/09/2020
Calculation method for determining air consumption of air compressor
The traditional method of determining the compressed air requirements of a new plant is to add up the air consumption (m³/min) of all air-consuming equipment, and then consider adding a safety, leakage and development factor.
-
08/17/2020
Why can't the cold storage temperature drop The evaporator is very important!
There are many reasons why the temperature of the cold storage cannot drop. The editor of okmarts.com lists the following six common phenomena for your reference:
-
09/13/2022
Dealing with Actuator Failures: Common Causes and Solutions
The actuator device is a combination of the actuator part and the control valve in automatic control system.
-
11/14/2022
How to Install an Industrial Exhaust Fan?
Factory production emits a lot of waste gas, and there are many workers gathered. For the sake of worker health and safety concerns, some exhaust fans are installed in factories to discharge exhaust gas.
-
08/21/2020
What to do in case of a trip Improper use of air conditioner can cause disaster
As soon as the air conditioner is turned on, the switch of this appliance immediately goes off. What is going on? Is there a problem with the wiring at home or the air conditioner?
-
11/02/2022
Detailed Classifications and Features of Electric Motors
Electric motors play an irreplaceable role in production, transmission and distribution. Each of them has their own structures, working principles, types of source power and applications.
-
07/01/2020
Talking about the advantages of compressor enthalpy increasing technology
Talking about the advantages of compressor enthalpy increasing technology The air-jet enthalpy-increasing compressor adopts two-stage throttling intermediate air-jet technology, and uses a flash evaporator to separate gas and liquid to achieve an enthalpy-increasing effect. This compressor jet enthalpy increasing technology has many advantages, as follows:
-
03/17/2021
Several common faults in the spindle drive system of CNC machine tools and how to repair it?
When the vertical machining center supporting FANUC6 system is working, the machine tool vibrated severely, and the AC spindle drive displayed AL-04 alarm. During the vertical machining center supporting FANUC6 system is working, the machine tool vibrates severely, and the AC spindle drive displays AL-04 alarm.