FUJITSU IC Integrated Circuit Chip MB89371A
Type: IC
Brand: FUJITSU
Type: IC
Brand: FUJITSU
Type: IC
Brand: FUJITSU
Siemens PLC 6ES7231-0HC00-0XA0
Winyao NIC Card WY580F2
SANREX IGBT Module DFA100BA160
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
IFM Sensor IFT228
Siemens Transmitter 7MF4033-1DA00-1BB7-Z
06/29/2020
How to calculate the number of Copeland compressors Copeland compressors are divided into L, C, 3S, 4S, and 6S series air-cooled compression and condensation units, which can be used as the main components of various refrigeration devices. The refrigerant can obtain various temperatures required for the preservation of fruits and vegetables, quick freezing of food or refrigeration. How to calculate the number of Copeland compressors?
06/14/2020
DF-IGC have Large flow with Compact body Innovative Double Flow Arrangement
09/08/2020
The difference between air-cooled screw machine and water-cooled screw machine: The oil cooler of the air-cooled screw compressor and the compressed air after-cooler are made into one body. It is an aluminum plate-fin structure and brazed in a vacuum furnace. Once the oil leaks, it is almost irreparable and only replaced. The working principle is that hot oil and high temperature (about 80℃) gas flow in their respective pipes,
02/18/2020
The principle of central air conditioning refrigeration The liquid Freon enters the evaporator through the capillary. The space suddenly increases and the pressure decreases. The liquid Freon will vaporize and absorb a lot of heat. The evaporator will become cold. The indoor unit fan will remove the indoor air from the evaporator. Blow through, so the cold air blows out from the indoor unit. Let's take a look at the cooling principle of the central air conditioner with the editor for your reference<img src="{{media url="magefan_blog/The_principle_of_central_air_conditioning_refrigeration.jpg"}}" alt="" />
01/31/2024
Wood stoves have been a reliable source of warmth for centuries, providing a cozy atmosphere during chilly days.
02/19/2024
Winters bring a sense of coziness as we rely on our furnaces to keep our homes warm and comfortable. However, discovering that your furnace is blowing cold air and refusing to shut off can be a cause for concern.
03/03/2021
Torque control: the torque control mode is to set the external output torque of the motor shaft through the input of external analog quantity or the assignment of direct address. For example, if 10V corresponds to 5nm, when the external analog quantity is set to 5V, the output of the motor shaft is 2.5nm: if the load of the motor shaft is lower than 2.5nm, the motor will rotate forward, and when the external load is equal to 2.5nm
12/29/2022
The programmable logic controller (PLC) is a digital operating electronic system specially designed for application in industrial environment.
03/18/2021
According to the current of the motor, use a driver that is greater than or equal to this current. If low vibration or high precision is required, a subdivision drive can be used. For high-torque motors, use high-voltage drivers as much as possible to obtain good high-speed performance.
03/18/2021
The larger the setting value, the higher the gain and the greater the stiffness. Under the same frequency command pulse condition, the position lag will be smaller.