Gree Air Conditioner KF-23GW-(23370)Ga-3
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Autonics Rotary Encoder ENA-600-2-T-24
Recent related posts
-
07/02/2020
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled In the summer, I believe that many people's feelings must be hot, scorching heat, sweating, etc. At this time, air conditioning is naturally essential equipment. If the air conditioner in your home is not cooling, then the air conditioner becomes a decoration.
-
01/09/2022
Heat Pump Compressor Troubleshooting
There are various types of compressors used in the heat pump unit and the fully enclosed piston compressor is the most commonly used type. However, when it’s in winter, there most probably are faults of this type of compressor due to frequent heating operations.
-
07/23/2020
Refrigeration compressor motor burnout detection and repair methods, quickly collect it!
The core component of the refrigeration system is the compressor. The faults of the motor refrigeration compressor (hereinafter referred to as the compressor) can be divided into motor faults and mechanical faults (including crankshaft, connecting rod, piston, valve plate, cylinder head gasket, etc
-
08/11/2020
8 main points of HVAC field construction experience
1. Equipment installation<br></br> 1. The installation location of the air-conditioning host should be convenient for inspection and repair, and should not affect its use function, especially pay attention to heat dissipation.
-
09/10/2020
Causes of Compressor Common Failures and Countermeasures Analysis
Abstract: During the operation of the compressor, some failures and even accidents will inevitably occur. A fault refers to an abnormal condition that occurs during the operation of the compressor, which can be restored to normal operation once the compressor is eliminated, while an accident refers to a damage situation. The two are often related, and if the fault is not eliminated in time, it will cause a major accident.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/27/2020
Compressor overhaul and correct installation matters, super complete and detailed
Content covered by compressor overhaul Compressors generally need to be overhauled after 12,000-26,000 hours of operation. In addition to all the work required for intermediate maintenance,
-
07/09/2020
Impact of COVID-19 on Global Gas Powered Air Compressors Market Outlook and Possibilities (2020-2029) || Hitachi, NorthStar, Rolair Systems
Study accurate information about the Gas Powered Air Compressors Market: Statistics, Facts and Figures, Growth Overview, Size, Major Players, Swot Analysis Industry Outlook and Regional Analysis, and Forecast To 2029. Extensive Study on Impact of the novel coronavirus (COVID-19) pandemic on the Gas Powered Air Compressors market originally based on Current Research of Potential Growth Challenges and Future Progress till 2029.
-
06/23/2020
What refrigerator is used for cooling
Most of them use fluorine-free refrigerants, and the models include R600A, R410A, R407A, R134A, etc., which are all green and environmentally friendly. The specific models are marked on the nameplate on the rear side of the refrigerator. the way.
-
08/20/2020
How to calculate air conditioner power-what is air conditioner power
The cooling power of the air conditioner refers to the total power consumed within the rated time when the air conditioner is in cooling operation, and the unit is W. It should be noted that the cooling power and cooling capacity are different.