Main electrical features
Frequency 50 Hz
Rated operational voltage Ue 230 V
Voltage
Rated insulation voltage 250 V
Command voltage AC 230 V
Rated impulse withstand voltage 4 kV
Electric current
Acceptable current load with AC7 category A 25 A
Acceptable current load with AC7 category B 8,5 A
Thermal rated current outside of housings 25 A
Power
Inrush power absorbed 10,7 VA
Operating consumption 2,9 VA
Contact rating with 230 V in AC7 category A 4,6 kW
Contact rating with 230 V in AC7 category B 880 W
Power loss per contact 1,5 W
Total power loss under IN 4,4 W
Power dissipation per coil 2,9 W
Tripping
Time of response when closing 25 ms
Time of response when opening 15 ms
Endurance
Electric endurance in number of cycles 30000
Number of mechanical operations 100000
Dimensions
Depth of installed product 60 mm
Height of installed product 83 mm
Width of installed product 17,85 mm
Fluorescent bulbs control
Max. load fluorescent lamp 950 VA
Max. power with fluorescent parallel lamps 810 VA
Fluorescent lamps in duo circuit 1990 VA
Incandescent bulbs control
Max. power with incandescent lamps 1900 W
Installation, mounting
Tightening torque 1,2Nm
Connection
Max cable connect. cross section (flexible) for
control
1 to 6 mm?
Connection cross-section of the control cable solid 1 to 10 mm?
Connection cross-sect. rigid cable 1 / 10mm?
Connection cross-sect. flexible conductor 1 / 6mm?
Type of connection with screw
Type of contacts 1NO
Equipment
Can be accessorized yes
Use
Local operation/hand operation no
Standards
European directive WEEE concerned
Safety
Protection index IP 2
Use conditions
Storage temperature -40 to 80 degrees Celsius
Identification
Device family ESC
Hager Contactor ESC125P
People who bought this item also viewed
Nader Contactor NDK1-80
Nader Contactor NDC1T-5011
RIKEN Contactor RAB-88T
CHINT Transformer NDK(BK)-2000
Hager Circuit Breaker MY716P C16
Ferraz Shawmut Fuse NH1UD69V80PV
Sensata-Crydom Relay ED24E5
UniOhm Resistor 25121WJ0223T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Sensor FQ2-S20010F
SAWANA Relay ST3PF DC12V 0-60S
SCHNEEBERGER Linear Guideway MRA25-G1V2
LG Compressor NR62L22A
MINDEO Bar Code Scanner CS2190
Recent related posts
-
06/14/2020
How to change the refrigeration oil of the compressor
The replacement of refrigeration compressor refrigeration oil is a relatively common item in refrigeration equipment maintenance projects, so many refrigeration workers hope that they can do this by themselves, but they are struggling to find a relatively ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄
-
06/14/2020
Development history of magnetic suspension refrigeration compressor
Development history of magnetic suspension refrigeration compressor
-
07/05/2020
Performance comparison of Mitsubishi, Hitachi and Daikin compressors
Compressor Daikin: domestic compressor, produced by Gree Mitsubishi: The original parts are imported! Won multiple energy-saving awards! Hitachi: Hitachi central air conditioners sold domestically are produced by Qingdao Hisense Hitachi Air Systems Co., Ltd.,
-
11/16/2022
What is an Axial Fan?
Axial fans, also called axial flow fans, are very versatile and produce airflow in the same direction as the axis of the fan blades.
-
07/12/2020
Future trends of semi-hermetic screw compressors? Unseen companies may be eliminated2
Future trends of semi-hermetic screw compressors? Unseen companies may be eliminated From single-screw to single-machine two-stage, from ordinary type to frequency conversion, environmental protection, energy-saving type, from a single product to the provision of system solutions, the development of semi-hermetic screw compressors has never stopped and has continuously penetrated into major refrigeration projects.
-
08/12/2020
Selection and Selection of Operation Mode of Ice Storage Process in Ice Storage Air Conditioning Ice storage process selection:
During the operation of the ice storage air conditioning system, the refrigerator can have two operating conditions, namely, ice storage conditions and cooling conditions.
-
08/27/2021
Why a Compressor is Used in the Refrigeration System
Why are refrigeration compressors used in small and medium-sized refrigeration systems? The compressor is the core equipment in the refrigeration system
-
12/20/2021
Battle of Giants - Differences of PLC by Siemens, Allen-Bradley and ABB
Many industrial equipment manufacturers in the world are producing PLC. The product and market competition between different companies is unavoidable.
-
04/28/2022
What is A Contactor?
Contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC). They are used in power, power distribution and electric field combination.
-
06/29/2020
Dehumidification technology with dual cold sources for clean air conditioners
Dehumidification technology with dual cold sources for clean air conditioners Compressors are used in many industries and in life, such as air conditioners that we cannot do without in summer. The air conditioner has a clean function and adopts dual cold source deep dehumidification technology. Composed of compressor, evaporator, condenser, refrigeration circuit, two-stage relay with cold water coil, can effectively achieve a minimum supply air dew point temperature of 8 ℃;