Displacement V 5- 31cc/rev
Speed n 500 - 4000 rpm
Pressure
rated pressure P, up to 276 bar
intermittent pressure P,up to 300 bar
Operating temperatures t up to 105° C
Average volumetric eficiency 97%
The maximum values for n, P, and tfor a given
pump specification may be applied
simultaneously.
Haldex Gear Pump 1300078
People who bought this item also viewed
HYDROMAX Gear Pump HGP-2AY-F8R
KOMPASS Check Valve CRG-06-A1
VTOZ Overflow Valve WDPHE-2631-2
YUKEN Piston Pump A10-F-R-01-H-K-10
YUKEN Vane Pump S-PV2R23-41-52-F-REAA-40
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BANDO Belt L-270-10
OKITA Relay MRR-2120S
NMB Sensor TMNR-50NM
NMB-MAT Fan 06025SA-24P-EL
SCHMERSAL Switch AZ-AZM200-B1-LT
Recent related posts
-
08/11/2020
How to check the air tightness of refrigeration equipment correctly
The refrigeration equipment is kept under a proper vacuum for a certain period of time. Whether the reading of the vacuum pressure gauge changes to reflect and observe whether the air penetrates into the system to check the sealing performance of the system.
-
06/14/2020
Centrifugal compressor
Centrifugal compressor
-
08/08/2020
Calculation method of weight per meter of air conditioner copper pipe
Calculation method of weight per meter of air conditioner copper pipe Everyone should know something about the air-conditioning copper pipe. The material of the air conditioner copper pipe is copper, which is pure copper.
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/17/2020
The heat pump is prone to frost between +4~-4℃. The symptoms and reasons are not beyond these 10 points.
The air source heat pump can use the low-grade heat energy in the ambient air, so it has the dual advantages of energy saving and environmental protection. However, one of the problems is that
-
06/14/2020
Failure analysis and analysis of other common failures of screw refrigeration compressor
The compression ratio of the screw machine is too large: it proves that this system completely deviates from the design value. The main phenomena are that the temperature of the exhaust temperature is too high, the suction pressure is too low, and the tem 器2 䀀 ᅵ皥
-
06/01/2022
How to Choose The Right PC Power Supply?
Power supplies are often overlooked, but they are a vital component in any desktop PC. We’re going to cover the basics, so you’ll know what to look for when selecting a new PSU.
-
07/06/2022
What is a Proportional Valve
A proportional valve provides a change in output pressure or flow in the same ratio as the change in the input, for example if the input doubles then the output will also double.
-
12/26/2022
What is a Programmable Logic Controller?
The programmable logic controller (PLC) is a digital operation electronic system specially designed for application in industrial environment.
-
07/20/2022
Common Types of Diaphragm Pump
An oil-free lubricating pneumatic diaphragm pump belongs to the field of pneumatic machinery.