There is no price at present, you can Request a Quote
HIWIN Linear Guideway HGR25R100C
There is no price at present, you can Request a Quote
People who bought this item also viewed
HIWIN Linear Guideway HGH15CAZ0C
HIWIN Linear Guideway EGH15CAC
HIWIN Linear Guideway QEH15CAZAC
HIWIN Linear Guideway HGH25HAH
SBC Linear Guideway SBI25HLL
NSK Linear Guideway LAH10ANZ
NSK Linear Guideway NAH45GM
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AVX Capacitor 20V 68UF
Omron Sensor E2B-M12KS02-M1-C1
AirTac Solenoid Valve 4V130-08
AirTAC Air Cylinder MARU50X500
Mean Well Power Supply SD-150D-12
AirTAC Air Cylinder SC63X430S
Recent related posts
-
06/14/2020
Analysis of common failure causes of totally enclosed refrigeration compressor
Analysis of common failure causes of totally enclosed refrigeration compressor Running end (R), starting end (S), common end (C), the resistance between RS is greater than that between SC and RC. The resistance between RS is equal to the resistance betwe ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/11/2020
How to maintain the lubrication system of the chiller
In the operation system of the chiller, more attention is paid to the refrigerant circulation system, the chilled water circulation system and the electrical control system of the refrigerator. The lubrication system is often overlooked. As everyone knows, this system is also very important to the chiller.
-
06/14/2020
Installation of ammonia refrigeration system in brewery
Installation of ammonia refrigeration system in brewery 1. Installation of ammonia refrigeration compressor unit Installation process flow: basic inspection and treatment of equipment → refrigeration compressor rough flat car → equipment in place → re 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ི
-
07/12/2020
To meet the needs of the refrigeration market, Danfoss 15HP refrigeration scroll compressor debut
The latest 15HP compressor MLM/MLZ116 is perfectly used in the fields of refrigerated and fresh-keeping storage, edible fungus storage, commercial refrigerated and refrigerated display cabinets, commercial ice machines, etc., helping unit manufacturers and engineering companies to reduce application costs.
-
08/14/2020
The correct way to open the refrigerated truck for summer maintenance
With the advent of summer, the maintenance of refrigerated trucks is becoming more and more important. In order to prevent the high temperature in summer from damaging the surface of the refrigerated truck,
-
06/27/2020
Compressor installation
Chapter 1 General Provisions Article 1 This chapter is applicable to the installation of reciprocating piston type, screw type, vane type and membrane type positive displacement compressors.
-
06/24/2020
How about the cooling effect of the air-conditioning fan
Air-conditioning fans are becoming more and more popular in summer. Of course, the price of air-conditioning fans is cheaper than air-conditioning. Of course, the cooling effect is not comparable to that of air-conditioning. So what about the cooling effect of air-conditioning fans? This is also a problem that everyone is more concerned about. In addition, the principle of the air-conditioning fan is also what you want to know. Let's take a look at the cooling effect of the air-conditioning fan with the editor, for your reference.
-
04/10/2024
Servo Control, Step Control and Variable Frequency Control: Detailed Explanation of the Three Major Controls
The following introduces the working principle, structure, types and application of the three major control methods of servo, step and variable frequency.
-
02/20/2024
Electric Furnace vs. Gas Furnace: Working Principle, Pros & Cons, Factors to Consider
As winter approaches and the need for a reliable heating system becomes paramount, the choice between an electric furnace and a gas furnace is a decision many homeowners must grapple with.