HIWIN Linear Guideway HGW45HBZAC
People who bought this item also viewed
HIWIN Linear Guideway EGH15CA
HIWIN Linear Guideway HGH20CAC
HIWIN Linear Guideway EGH15CAZOC
HIWIN Linear Guideway HGW35HCC
HIWIN Linear Guideway HGW30HC
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder SDAT80X10X20
Lodestar Power Supply LP303DA
SMC Proportional Valve ITVX2030-333BL3
FUJITSU Relay FTR-B3GA003Z
Recent related posts
-
09/15/2020
Matching selection for small internal compression process design
As a traditional process type, small internal compression process equipment has been produced in the okmarts.com factory for many years. It is well received by users for its inherent advantages.
-
04/06/2022
How to Make an Air Conditioner With a Fan?
The weather in summer is pretty hot . If there is no air conditioner at home, only the electric fan can we use to cool down. If we still feel hot after turning on the fan, in fact, we can make an electric fan as cool as an air conditioner by ourselves.
-
06/08/2023
What Does a Bad AC Compressor Sound Like?
Your air conditioning (AC) system is designed to keep you cool and comfortable during the hot summer months.
-
08/20/2020
How to detect the tightness of the refrigeration equipment system
Keep the refrigeration equipment under a proper vacuum for a certain period of time, and observe whether the air infiltrates the system from the reading of the vacuum pressure gauge to check the sealing performance of the system.
-
06/21/2020
The classification of piston compressor_The advantages and disadvantages of piston compressor Classification of piston compressor
The classification of piston compressor_The advantages and disadvantages of piston compressor <img src="{{media url="The_classification_of_piston_compressor.jpg"}}" alt="" />Classification of piston compressor (1) Classification according to the position of the cylinder centerline Vertical compressor: The center line of the cylinder is perpendicular to the ground. Horizontal compressor: The center line of the cylinder is parallel to the ground, and the cylinder is only arranged on one side of the fuselage.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
11/16/2022
How to Fix an Industrial Fan?
Industrial fans can effectively control the air circulation in industrial production workshops. However, industrial fans can also fail due to improper use and prolonged use.
-
06/14/2020
Development history of magnetic suspension refrigeration compressor
Development history of magnetic suspension refrigeration compressor
-
09/10/2020
The high-voltage inverter market has huge potential, expecting technological breakthroughs
The high-voltage inverter has a significant energy saving effect. Without changing the host equipment, only changing the speed can achieve an average power saving effect of 30%. Among them, the average energy saving rate of petroleum system is 38%, petrochemical system 46%, metallurgical system 42%, urban water supply and drainage system 45%, chemical industry System 24%.