There is no price at present, you can Request a Quote
We can also provide the following models
TLE 2.5 R404A MOP A ±0 °C 3/8" X 1/2"
TLE 2.5 R404A MOP A -18 °C 10mm X 12mm
TLE 2.5 R404A MOP A -18 °C 3/8" X 1/2"
For more information,please contact us freely
Honeywell Expansion Valve TLEX-00175
There is no price at present, you can Request a Quote
People who bought this item also viewed
Danfoss Expansion Valve 068U2963
Danfoss Expansion Valve 067N2015
Danfoss Expansion Valve spool 067B2092
Bristol Compressor H82J46BABC
CKD Solenoid Valve M4GD110R-C4-3-3
Block Transformer PT13/2/6
Siemens Contactor 3RT1075-6SP36-3PA0
SUNON Fan MEC0252V3-000C-A99
GGM Electric Motor K9IP150FM-C50
Ingersoll Rand Filter 54749247
EMERSON Sight Glass AMI-1SS3
Toshiba Expansion Valve Coil YB12M
MALLORY Capacitor LPX 450V 120UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SHAKO Air Cylinder IC50C400
Kwangwoo KW Encoder RIA-40-0100ZT
Rockwell A-B Sensor 871TM-DH2CN12-C2
KOGANEI Solenoid Valve V112-4E1-PLL
Recent related posts
-
08/19/2020
Why do industrial chillers need to replace high-quality antifreeze regularly
When the industrial chiller is running, there are high requirements for the use of antifreeze. Ordinary equipment cannot use high concentration antifreeze. If the concentration of antifreeze is high, it takes a long time to warm up before operating the equipment.
-
09/21/2020
Cold dryer knowledge
Refrigeration unit refrigeration capacity conversion table
-
03/12/2021
Four control modes of servo drive
1.Feedback compensation open loop control. The accuracy of open-loop system is low, because the step error , start stop error and mechanical system error of servo driver will directly affect the positioning accuracy. This system has the advantages of both open-loop and closed-loop, that is, it has the stability of open-loop and the accuracy of closed-loop.
-
03/16/2021
FANUC spindle drive repair fault treatment
FANUC spindle drive maintenance problems mainly appear as stalls, abnormal speeds, motor oscillations, jitter during processing, and main circuit overcurrent alarms. Compared with AC FANUC spindle drive maintenance problems, the primary manifestations are motor overvoltage, fuse blown, etc.
-
02/13/2024
A Comprehensive Guide to Parts of a Furnace
When winter arrives and the chill sets in, a reliable furnace becomes a crucial component of any home's heating system.
-
07/03/2020
Portable Oil Free Air Compressor Market Size 2020-2026 Review, Key Findings, Growth Strategy, Developing Technologies, Trends And Global Forecast By Regions
The Stationary Oil Free Air Compressor Market report includes overview, which interprets value chain structure, industrial environment, regional analysis, applications, market size, and forecast. This is a latest report, covering the current COVID-19 impact on the market. The pandemic of Coronavirus (COVID-19) has affected every aspect of life globally.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/15/2020
Installation, selection and adjustment of air conditioner flow switch
Water flow switches are also called flow switches. Water flow switches are widely used in water systems of chillers and air conditioning projects. It can ensure the safe and efficient operation of air conditioning systems.
-
06/14/2020
Causes and harms of non-condensable gas produced by refrigeration system
Non-condensable gas refers to air, hydrogen, nitrogen, lubricating oil vapor, etc. mixed in the refrigeration system.
-
01/06/2021
Explanation of the phenomenon of natural wind when heating the central air conditioner for a period of time
Explanation of the phenomenon of natural wind when heating the central air conditioner for a period of time Explanation-of-the-phenomenon-of-natural-wind-when-heating-the-central-air-conditioner-for-a period-of-time Friends who use heating in winter w 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ғ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴