Honeywell Input Output Module XFL822A
People who bought this item also viewed
Kuroda Module A40PW-01U-1Y100
Kuroda Module PTB-H08P2A-C
Beckhoff Module BC8050
Kuroda Module PTB-08P2A
Yaskawa Servo Motor SGMGH-13A2A-YR23
Bosch Rexroth Servo Drive DSC 1.7-50-115V
HENGSTLER Encoder RI58-O/10000AS.41RC
Schneider Analog output module PLC TM5SAO2L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Balluff Sensor BSP00PN
EMAUX Water Pump EPH400 220V
IRC Resistor RNC65H2614FM
NACHI Vane Pump VDC-22B-1A2-1A5-20
Johnson Controls Actuator VA9208-GGA-1
Recent related posts
-
04/18/2023
How a Refrigeration Compressor Works
The refrigeration compressor is the core component of the refrigeration unit, and plays a decisive role in the running performance, noise, vibration and service life of the system.
-
01/04/2021
Noise control of a two-stage screw refrigeration compressor
Noise control of a two-stage screw refrigeration compressor From a Department of Compressor Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, 710049 Shaanxi, China b Suzhou Academy, Xi’an Jiaotong University, 215123 Jiang 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ
-
04/05/2023
10 Causes of AC Compressor Failure & 4 Ways to Prevent It
When the weather is very cold or hot, once the air conditioner fails, it will be miserable. So it is necessary to know the possible faults of an air conditioner compressor and some preventive ways in advance.
-
08/14/2020
The correct way to open the refrigerated truck for summer maintenance
With the advent of summer, the maintenance of refrigerated trucks is becoming more and more important. In order to prevent the high temperature in summer from damaging the surface of the refrigerated truck,
-
06/21/2020
Common system failures of refrigeration equipment
Common system failures of refrigeration equipment 1. Liquid return: For refrigeration systems using expansion valves, liquid return is closely related to the selection and use of expansion valves. Expansion valve selection is too large, the superheat setting is too small, the installation method of the temperature sensor is incorrect, the insulation bandage is damaged, and the expansion valve failure may cause liquid return.<img src="{{media url="Common_system_failures_of_refrigeration_equipment2.png"}}" alt="" />
-
06/30/2020
What are the factors that cause motor damage?
What are the factors that cause motor damage? What are the factors that cause damage to the compressor motor: 1. Abnormal load and stall
-
01/29/2022
Refrigeration Compressor Frosting Reasons & Solutions
When we use the refrigeration compressor, there could be frosting. It’s a failure that we can solve.
-
10/25/2021
How to Use Rotary Encoder on Arduino Board UNO
In our last article, you may have learned how to connect a rotary encoder on Arduino development board UNO.
-
04/11/2024
12 Linear Servo Motor Manufacturers Worldwide
linear servo motor refers to a motor that can accurately control linear motion. It is one of the key components in linear servo systems and is mainly used in industrial production, healthcare, printing and packaging.
-
08/30/2021
How to Fix a Refrigerator Compressor?
The refrigerator compressor is the core of a refrigerator and achieves the cooling effect. Due to the frequent use of the refrigerator