Honeywell Switch BZ-2RW822-A2
People who bought this item also viewed
Omron Switch D4B-2A71N
DANFOSS Switch MBC 5180
Siemens Switch 3SU1002-2BM10-0AA0
PILZ Switch PSEN sl-0.5p 1.1 1switch
Eaton Contactor DILM12-01(48V50HZ)
SHOWA Overload Pump OLP8-H-L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
WECO Light Curtain WECO-917Y61-AC220
MAHLE Filter LAK508
CML Solenoid Valve WE43-G02-C2-A110-N
Recent related posts
-
06/22/2020
What is the air conditioner that only cools
An air conditioner with only a cooling function is called a single cooling type air conditioner. 1. The single-cooled air conditioner is used in areas in the north or the south that are not cold in winter; 2. The single-cooled air conditioner model generally starts with KF; 3. Before you use the single-cooled air conditioner again, you need to clean and maintain first; 4 1. When using a single-cooling air conditioner in summer, the temperature cannot be set too low. Generally, the air conditioner temperature should be set to 26-27 degrees. <img src="{{media url="magefan_blog/What_is_the_air_conditioner_that_only_cools.jpg"}}" alt="" />
-
01/07/2021
The method to identify the failure of the totally enclosed refrigeration compressor is very effective!
The method to identify the failure of the totally enclosed refrigeration compressor is very effective! 1. How to identify the three binding posts on the casing of the hermetic compressor? Running end (R), starting end (S), common end (C), the re 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱
-
05/12/2022
What is the difference between copper pipes using R410A refrigerant and R22
The central air-conditioning copper pipe is the medium of air-conditioning and heating transmission, which is equivalent to the connection of human blood. Fluorine system household
-
06/29/2020
Analysis of the cause of excessive suction temperature of compressor
Analysis of the cause of excessive suction temperature of compressor The high suction temperature is mainly due to the increase of superheat of suction. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam. Under normal circumstances, the compressor cylinder head should be half cold and half hot. If the suction temperature is too high, the cylinder head will all heat up.
-
09/04/2020
Graphic-the structure of air compressor
An air compressor is an air compressor. It is a device that provides compressed air to various workshops in the factory. It compresses the atmospheric air sucked in from the outside through mechanisms such as screws and bolts
-
12/12/2021
How to Add Encoder to Stepper Motor
When the current flows through the stator winding, the stator winding produces a vector magnetic field. The magnetic field will drive the rotor to rotate an angle, so that the direction of magnetic fields of the rotor is consistent with that of the stator.
-
09/23/2020
Installation foundation of compressed air pipeline
Basic knowledge is very important for sheet spray work, and the same is true during equipment installation. When installing compressed air pipelines, everyone must pay attention to the following precautions:
-
07/30/2020
About inverter air conditioner fault repair skills
Today I will share with you the maintenance ideas and cases about the failure of the inverter air conditioner that does not heat but can cool. If you like, you can like it and collect it, thank you!!!<br></br>
-
06/14/2020
What to do if the screw chiller compressor is damaged
The compressor is the core component of the chiller. Damage to the compressor is a serious fault that needs to be dealt with in time, otherwise the chiller will not work. Today, the editor will introduce the knowledge and process of handling damaged screw 器2 䀀
-
10/23/2023
Air Conditioner Line Frozen: Causes, Troubleshooting and Prevention Methods
When the air conditioner line freezes, it can be a frustrating experience for homeowners. Not only does it disrupt the cooling process, but it also indicates an underlying issue that needs to be addressed.