The refrigeration compressor exploded! Personal experience tells the whole process...

The refrigeration compressor exploded! Personal experience tells the whole process... A person who experienced the explosion of a refrigeration compressor recalled the explosion and injury! I hope that readers can draw attention after reading, and follow the procedures when operating refrigeration compressors in the future to avoid explosion accidents! The whole process of things happening: An air conditioner external unit was dismantled and repaired. There is a lot of oil in the external unit. There should be leaks, but the normal pressure is not enough. The pressure is not enough. A colleague came up with the idea that the nitrogen pressure is enough to start the machine. It may be an illegal operation, but it should be no problem if the pressure is controlled well! The first time I heard, try it, after all, people have been doing it for many years! Another colleague went to turn on nitrogen, and we crouched next to the compressor to see the pressure. He meant 2.5 pressures! About 10 to 20 seconds, I can't remember clearly. I only know that when the pressure gauge reaches 2 pressures, with a bang, I came out with my face covered! At that time, I couldn't hear anything, and I couldn't see anything. I tried to open my eyes, my eyelids hurt, and my face hurts! I felt my hair burn into a curl, I endured the pain and opened my eyes to see that all the hands after touching the face were blood! I crouched beside the door and wanted to disfigured! The neighbor ran over to me and let me sit down and slowly opened my eyes, saw a piece of meat blown out of the arm, not big but very deep, probably the thumb can be inserted diagonally! His arms turned into honeycomb coal, all of which were scalded meat and debris and oil. He turned his head and saw that there were more than 500 people standing on the roadside watching the bustle. My friend called 120, and the other one was carried out, and then the wound was wound in the hospital. The colleague lived directly in the intensive care unit! My colleague only came out of the intensive care unit on the day I was discharged from hospital for ten days! The arm and face are covered with skin trauma, and the face is just about seven days away. The stitches have not been stitched except for the arm. Because the high temperature face has a layer of skin, there is no scar left. germination! I know how loud it is because my eardrum was ruptured and I have to wait for the arm to be removed before I have surgery! Colleague's injury: 3 stitches on the mouth, broken brow bone, broken skull! Another experienced a compressor explosion operator: The approximate process is: a 1.5p hook-up compressor sounds relatively loud, so I think the compressor may be short of oil, and this air conditioner has leaked. The two colleagues decided to replenish the compressor with refrigeration oil. When removing the suction port and filling the freezing oil, the freezing oil could not go down. A teacher said that the compressor was started to suck in, so he asked another colleague to go in and start to refuel, after adding some freezing oil, he got up Ask a colleague to turn off the machine and say yes. Before they left the air conditioner, they heard a loud noise. The compressor exploded, the air conditioner casing was exploded, and both ears were suddenly deaf. They didn't recover until they went to the hospital. At that time, if it didn't get up, it exploded. It is estimated that it was similar to the injury of the two people above, and it blasted directly to the head. Remember not to operate in violation of regulations, only one life, safety first. Through the above description of the two victims who personally experienced the explosion of the air conditioner compressor, everyone also has an understanding of the hazards of the compressor explosion, so what problems should we pay attention to in normal operation? There are many reasons for the air conditioner not cooling, and it is necessary to conduct a comprehensive inspection of the operation of each part of the air conditioner to find out the specific fault and repair it. Among them, there are leaks in the system, and refrigerant leakage is one of the reasons why the air conditioner does not cool. In actual operation, the following illegal operations often occur during the leak detection of the refrigeration system: 1 Violation of the leak detection operation caused the compressor to explode Operation process: close the high-pressure valve → turn on the compressor → use the compressor to charge the outdoor unit refrigeration system with air to pressurize, so as to check the leak point → run for several minutes. Result: The compressor exploded. Process analysis: mainly for the danger of compressor suction air operation, there is a certain amount of refrigeration oil inside the compressor (the random type varies from 350cc to 950cc). Under certain pressure and temperature conditions, the refrigeration oil will spontaneously ignite, causing compression The abnormal high temperature and high pressure inside the machine will eventually cause the compressor casing to rupture and then explode. Conditions for refrigeration compressor explosion: The high-pressure side of the refrigeration cycle system of the air conditioner is blocked; Compressor operation; Inhale air; The mechanism of compressor explosion; The high-pressure side of the refrigeration cycle system of the air conditioner is blocked; Compressor operation; Inhale air for a few minutes; The compressor is overheated; Refrigerator oil is overheated and vaporized; The oil and gas mixture inside the compressor increases a lot, and the temperature and pressure continue to increase; At a certain pressure and temperature, the oil and gas mixture in the compressor spontaneously ignites, and the temperature and pressure rise sharply; Compressor shell compressive strength is exceeded and compressor shell burst occurs. Responses: During the inspection of the leakage point of the refrigeration system, the compressor of the air conditioner must not be used to suppress the pressure. 2 Violation of refrigerant recovery operation when moving the machine caused the compressor to explode Air conditioner transfer is also a regular business, and refrigerant recovery is required during the transfer process. However, if improper operation, it will also cause serious consequences of compressor explosion. Operation process: Compressor operation → Close high pressure valve → Inhaled air leakage from low pressure side of air conditioner system → Operation for several minutes → Compressor explosion. Process analysis: Due to the leakage point of the air conditioning refrigeration system, there is no refrigerant or a small amount of refrigerant left in the system due to the leakage point on the low pressure side, which causes the compressor to suck air and operate with the high pressure side turned off, and eventually an explosion occurs. The conditions and mechanism of refrigeration compressor explosion are the same as above. Countermeasure: Before moving the air conditioner to the machine, the air conditioner must be turned on to check the operating parameters. When confirming that the performance parameters are normal, connect a pressure gauge to the three-way valve process tube before closing the high-pressure valve for refrigerant recovery, and stop when the pressure is 0.1MPa.

Recent related posts

Customers frequently viewed

Submitted Successfully
Submission Failed