Rated Insulation Voltage V 1000
Rated Operational Voltage V 1000
Ith (AC1) A 260
AC-3 200-240V kW/A 63/220
AC-3 380-440V kW/A 110/220
AC-3 500-550V kW/A 132/200
AC-3 660-690V kW/A 132/150
AC-4 200-240V A 180
AC-4 380-440V A 180
AC-3 (le) Lifetime Electrical x10,000 times 1,000
AC-3 Lifetime Mechanical x10,000 times 5,000
HYUNDAI Contactor HIMC220
There is no price at present, you can Request a Quote
People who bought this item also viewed
HITACHI Contactor A150
RIKEN Contactor RAB-A80
RIKEN Contactor RAB-125N
Nader Contactor NDK1-80
Delixi Transformer QZB-45KW
SQUARE D Circuit Breaker HGA260204
Tyco Fuse RUEF200
HONGFA Relay HFKP-024-1Z5TS
Siemens Resistor 6SE7023-2ES87-2DC0
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve SQ2131-5-L6
HONGFA Relay HFV16-12-H4T-D(101)
TOYOOKI Vane Pump HVP-FC1-L5R-A 2200
Panasonic Servo Motor MSMF022L1V2
Recent related posts
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
08/14/2020
How to reduce the overall cost of purchasing industrial chillers
How to reduce the overall cost of purchasing industrial chillers
-
12/18/2021
Basics of Encoder and Orthogonal Coding
Encoder is a kind of electromechanical equipment, which can be used to measure the movement of machinery or the target position of machinery.
-
09/08/2020
The life of air compressor bearings and the causes of damage
If the air compressor loses one bearing or does not pay attention to the correct use of the bearing, the air compressor will not be able to operate normally, and it will greatly shorten the service life of the bearing, which will bring us unnecessary losses.
-
08/14/2020
How to deal with moldy cold storage accessories
1. Analyze the reasons<br></br> Inspect the entire refrigeration system to confirm the cause of frost damage and find out the leaks
-
08/18/2020
Common faults and maintenance methods of air-cooled chillers
Air-cooled chillers are installed outdoors without any obstruction, and are easily affected by outdoor light. So how to maintain good ventilation, good environment and space has a key impact on the cooling effect of the chiller.
-
06/14/2020
Frequently asked questions about refrigeration compressors, do you know these
Frequently asked questions about refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
12/20/2022
What is an Optical Fiber Amplifier?
The optical fiber amplifier, also known as the optical fiber ampler (OFA for short), refers to a new type of all-optical amplifier used in optical communication link to realize signal amplification.
-
09/04/2020
Although the air compressor safety valve is small, it has a huge effect
Regardless of the small size of the valve of the air compressor, its function should not be underestimated. Just like the screw air compressor safety valve, it is a "small thing" installed on the oil and gas barrel
-
09/06/2020
The difference between variable frequency air compressor and industrial frequency air compressor
The difference between variable frequency air compressor and industrial frequency air compressor: 1. The pressure is stable: