Electrical design PNP
Output function normally open
Sensing range [mm] 10
Housing threaded type
Dimensions [mm] M30 x 1.5 / L = 80
Application
Application simple evaluation of rotating and linear movement with regard to under speed; blocking
Electrical data
Nominal voltage DC [V] 10...36
Current consumption [mA] < 20
Protection class III
Reverse polarity protection yes
Outputs
Total number of outputs 1
Electrical design PNP
Output function normally open
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 250
Short-time current rating of switching output [mA] 250
Short-circuit proof yes
Overload protection yes
Detection zone
Sensing range [mm] 10
Sensing range adjustable no
Operating distance [mm] 0...8.1
Measuring/setting range
Setting range [Imp/min] 5...3600
IFM Sensor DI5024
People who bought this item also viewed
IFM Sensor IGS312
IFM Sensor PI1698
IFM Sensor PI2798
IFM Sensor IT5040
Contrinex Sensor LLR-C23PA-NMS-404
Honeywell Sensor H7508B1080
Honeywell Sensor H7080B1105
FOTEK Sensor A3T-10MXB
Meas Transmitter MSP-400-500-P-3-N-1
Fireye Flame Detector 48PT2-1003
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder MARU40X325S
DEKEMA Vane Pump 50T-36
PIZZATO Switch FL E104-M2
Daikin Air Conditioner FTXR226UC-N1
ITECH Power Supply IT7622
JOHNSON Electric Motor 1D60074
Recent related posts
-
06/22/2020
Why is the air conditioner not cooling
Why is the air conditioner not cooling There are many factors for not cooling, for example: the selected air conditioner does not match the area of the room; improper installation of the air conditioner will cause the air circulation of the air conditioner to be unsmooth; when the indoor temperature is relatively high, the air conditioner cannot be cooled when turned on; It has been aging, or the service life has expired; the air conditioner has not been cleaned for a long time, and the filter surface is covered with dust; and the freon of the air conditioner has been seriously lacking. <img src="{{media url="magefan_blog/Why_is_the_air_conditioner_not_cooling.jpg"}}" alt="" />
-
07/05/2020
Hitachi screw compressor failure case
Hitachi screw compressor failure case The author summarizes the case of Hitachi screw compressor maintenance and replacement bearings, and shares the data, please send it to a friend to collect and forward it for use
-
01/13/2022
Rotational Inertia of Servo Motor
Servo motor refers to the motor that controls the operation of mechanical components in a servo system. Its rotor speed controlled by the input signal can respond quickly.
-
08/07/2020
Have you gotten the troubleshooting method of the spring chiller?
Have you gotten the troubleshooting method of the spring chiller?<br></br> The cold will go all night, and the spring will come again. "At 5:29 on February 4, 2018, the northern hemisphere of the earth where we live entered the beginning of spring of the ﰨ2 䀀 湠疌 V ǜ V 㠠ư㠠ư㠠ư類 湠疌疀ꝆဠЀ
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser
-
09/19/2022
What are the Main Parameters of a Molded Case Circuit Breaker?
Molded case circuit breakers can automatically cut off the current after the current exceeds the trip setting.
-
06/14/2020
What is the effect of pressure and temperature on the refrigeration system
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
06/22/2020
What's wrong with air conditioning and cooling
1.The air conditioner lacks freon. Under such circumstances, the air conditioner cooling effect will be poor. 2. If there is a lot of dust and dirt in the filter, it will affect the heat dissipation effect, which will affect the cooling. 3. The outdoor temperature is too high, and it is difficult to lower the temperature by turning on the air conditioner at home. 4. Voltage problem, the power supply voltage of normal air conditioner is 220V, but if it is lower than 220V, the cooling effect will be greatly affected. Summer is coming soon, and the weather is getting hotter. But if the cooling effect of the air conditioner is not good after turning on, what is going on? Is there any good solution? <img src="{{media url="magefan_blog/What_s_wrong_with_air_conditioning_and_cooling.jpg"}}" alt="" />
-
12/10/2021
Top 10 Brands of HMI Worldwide
HMI is the abbreviation of human machine interface, which is also known as user interface. It is the medium of interaction and information exchange between the system and users.
-
05/17/2023
How to Add Oil to AC Compressor
When the all-in-one air conditioner leaves the factory, there is a sufficient amount of AC compressor oil (commonly known as refrigeration oil, refrigerant oil, AC lubricants, AC oil) inside the machine.