0...250 bar;
0...3625 psi;
G 1/4 external thread;
switching signal;
Connector;
Schneider Sensor XS1D18PA140
TAKEX Sensor UM-TR15DT
IFM Sensor IT5040
IFM Sensor IGS312
IFM Sensor PI2798
IFM Sensor PI1698
Contrinex Sensor DTL-C55PA-TMS-119-503
Honeywell Sensor 40PC250G3A
TAKEX Sensor GTR3RSPN
Banner Sensor SM312LVQD-50939
Danfoss Transmitter 060N1224
Honeywell Flame Detector 16531U
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
WINMOST Solenoid Valve WD-G03-B5B-D2-N
MINDMAN Air Cylinder MCQA-11-125-410
HITACHI VFD Frequency Converter SJ700-075LFU
08/20/2020
The cooling power of the air conditioner refers to the total power consumed within the rated time when the air conditioner is in cooling operation, and the unit is W. It should be noted that the cooling power and cooling capacity are different.
07/18/2020
The application of screw refrigeration compressors is becoming more and more common, and some of them have entered the period of frequent failures. When the abrasion of the female and male rotors, body, and exhaust end seat of the refrigeration compressor reaches above 0.65rnm, vibration will occur when the refrigeration compressor is running, the sound is abnormal, the cooling capacity is reduced, and the compressor cannot work normally.
09/07/2020
The gas storage tank is a part of the post-processing equipment of the air compressor, which mainly plays the role of gas storage, buffering, pressure reduction, and drainage. It will inevitably cause corrosion in the air, rain or humid atmosphere after long-term use or use for many years.
08/26/2020
Screw compressors, also known as screw compressors, are divided into single screw compressors and twin screw compressors. The single screw compressor was developed by Sinn, France in the 1970s.
06/20/2020
Common fault phenomena, causes and elimination methods of piston compressors Common faults of piston compressor (1) Phenomenon: the compressor cannot start Reasons: 1. Electrical circuit failure; 2. High and medium voltage relay and oil pressure relay are disconnected.<img src="{{media url="Common_fault_phenomena_causes_and_elimination_methods_of_piston_compressors.jpg"}}" alt="" />
08/19/2020
The correct installation of the thermal expansion valve will also affect the performance of the refrigeration device. Before installation, check whether the expansion valve is in good condition, especially the temperature sensing mechanism.
11/26/2021
In industry, it is necessary to measure all kinds of electric and non electric parameters, such as current, power, temperature, pressure, speed and angle, etc.
10/25/2023
Choosing the right cooling system for your home or office is essential for creating a comfortable and pleasant environment. Two popular options are mini-split air conditioners and window AC units. Each system has its unique advantages and considerations.
05/29/2023
Air conditioning systems have several components that assist in the cooling of the air. These components are the compressor, condenser and evaporator.
05/15/2022
The cylinder is a cavity ( in which the piston is placed ) on the block of the internal combustion engine. It is the track of piston movement in which gas burns and expands.