Basic dynamic load rating: C 67900 N
Basic static load rating: C0 75500 N
IKO Linear Guideway LRWM5H Linear way module
People who bought this item also viewed
IKO Linear Guideway LWLF42 Linear way L
NSK Linear Guideway LAH10ANZ
NSK Linear Guideway NAH15AL
MPM Printing Machine Parts 1014950
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Delta PLC HostDVP28SV11T2
Dwyer Switch SA1111E-S5-K1
Recent related posts
-
05/02/2022
Differences Between AC Contactor and DC Contactor?
The working principle of DC contactor is similar to that of AC contactor. They all make the main contact on or off through the actuation of electromagnetic coil.
-
07/23/2020
Analysis of common failure causes of hermetic refrigeration compressors
1. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.<br></br>
-
08/12/2020
Have you figured out the "enthalpy" and "entropy" of the refrigeration system?
1. Enthalpy<br></br> It is a kind of energy, used to indicate the thermal state parameter of the state of the refrigerant, it represents the size of the total energy of the refrigerant; namely:
-
04/03/2024
24 Famous Industrial Robot Companies Worldwide
In recent years, the robot industry has risen rapidly around the world. At present, five major robot development areas have been formed, in Europe, the United States, Japan, China, and South Korea. The following lists 24 representative robot companies. Let’s take a look.
-
08/14/2020
Maintenance method of ultra-low temperature chiller refrigeration system
An ultra-low temperature chiller refers to a refrigeration unit whose chilled water temperature reaches below minus 35°C. The unit adopts two-stage compression refrigeration.
-
07/26/2020
Common faults and troubleshooting methods of refrigeration compressors
The compressor is the "heart" of the refrigeration system. The compressor sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and then discharges the high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle to realize the refrigeration cycle. The editor summarizes the common faults and troubleshooting methods of the compressor to help you better maintain the compressor.
-
06/13/2020
Disassembly and failure analysis of scroll compressor
The scroll compressor is a positive displacement compression compressor, and the compression component is composed of a movable scroll and a static scroll. This includes many structural features that divert the flow of gas through the compressor housing t 器2 䀀 ᅵ皥
-
12/15/2023
HVAC Fan Won't Turn off (Troubleshooting Guide)
Having a properly functioning HVAC system is essential for maintaining a comfortable and controlled indoor environment.
-
08/02/2020
How to determine the refrigerant leakage of the air conditioning system Only need these six steps
Shut down and unplug the air conditioner (to prevent danger during the inspection process), and connect a pressure gauge to the large valve. Observe the static pressure.
-
07/31/2020
What kind of equipment is suitable for high and low pressure refrigerant charging method
There are generally two types of refrigerant charging methods: low-pressure charging and high-pressure charging. The advantage of the low pressure charging method is that it is easier to control the amount of refrigerant charged,