Cold start function:Yes, the default setting output frequency is 50HZ
Input voltage range:110-288VAC/100% load @>176VAC; 80% load @>154VAC; 70% load @>132VAC; 50% load @>110VAC
Input frequency:40Hz-70Hz
Rated output voltage:220VAC+-1%
ECO mode:91%
Dimension:190*374*336
Invt UPS Power Supply HT1102L-TX
People who bought this item also viewed
GE Power Supply LED150CV12EMS
Panasonic Servo Motor MHME204G1C
Endress Hauser Transmitter FMX167-A3AMD1A3
KOYO PLC D3-08B-1
Delta Fan EFC1212D
COPAL Electric Motor FH6-1650
IXYS Rectifier Module VUO62-18NO7
Delixi Relay CDG1-1DD 25A
FLUKE Battery BP1735
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder SE125BX25
HENGSTLER Encoder AC58/1212EF.47SGH
EMERSON Power Supply UHA1R-0100L
Recent related posts
-
08/17/2020
How to adjust the refrigeration system of cold storage equipment to reduce operating costs
1. Reasonably adjust the operating parameters of the refrigeration system to improve equipment efficiency. The evaporating pressure and temperature of the refrigeration system and the condensing pressure and temperature are the main parameters.
-
08/17/2020
Analysis of 4 major reasons for the high energy consumption of building HVAC systems
1. Analysis of the high energy consumption of the building HVAC system The reasons for the high energy consumption of building HVAC systems are mainly reflected in the following aspects:
-
07/20/2020
How to eliminate the difficult problems of the salt spray test chamber
Many people will blame the poor quality of the salt spray test box in actual use. However, the relevant departments have used statistical data to tell us that more than 50% of these problems are caused by operation. Only 5% is the quality problem of the salt spray test box itself.
-
10/17/2021
Maintenance of Absolute Encoders
What are the precautions for maintenance of rotary encoders? Rotary encoders are used as speed and displacement feedback sensors, which are mainly applied in servo motors, asynchronous motors
-
06/28/2020
Which air conditioners are used by Hitachi compressors
Hitachi compressor technology is mature, good quality, reliable performance, is the first compressor used by Gree, Midea, Chigo, Haier and other air-conditioning manufacturers. okmarts.com is an authorized dealer of Hitachi compressors, with complete specifications and sufficient supply, which can meet your purchasing needs at any time.
-
03/09/2023
Introduction to Three Sorts of Soft Starters
Soft starter, in essence, is a reduced-voltage starter that can control automatically. As it can adjust output voltage arbitrarily, plays a role in current closed-loop control
-
08/14/2020
How to choose cold storage cable
In the process of cold storage installation, cables are an indispensable material. Although we can see a lot in the market, these cables and wires are also classified in different ways, and the power they can support is also different.
-
09/02/2020
There are 8 reasons for the high fuel consumption of air compressors, some of which can't be thought of!
Run oil In our daily work, we often encounter the problem of air compressor running oil. In addition to the quality of the oil itself, what other reasons can cause the running oil? In practice, engineers have summed up several reasons that can cause oil running. Let's share with you.
-
07/15/2022
What is a Gear Pump
Gear pump is a rotary pump that transfers liquid or pressurizes it relying on the change and movement of the working volume formed between the pump cylinder and the meshing gear.
-
06/13/2020
Common failures of half-sealed piston compressors
Common failures of half-sealed piston compressors 1. The compressor cannot start normally 1. First check whether the power supply voltage is too low or the motor line is poorly connected. If the grid voltage is too low, start again after the grid volt 器2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵