Maximum output power of single channel up to 150W, output voltage max.+/-30V, output current max.+/-5A (IT6432)
Dual channel, bipolar, dual range output (IT6412)
High output voltage and current resolution: 1mV/0.1mA
High output voltage and current accuracy: < = 0.02percent + 3mV/< = 0.05percent + 2mA in max
High voltage and current readback resolution: 1mV/100nA at 5mA range and 1mA at 5A range
High output voltage and current readback accuracy:
< = 0.02percent + 2mV/< = 0.05percent+0.000002A at 5mA range and < = 0.05percent+2mA at 5A range (IT6411, IT6412)
< = 0.02percent + 3mV/< = 0.05percent+0.000002A at 5mA range and < = 0.05percent+2mA at 5A range (IT6432)
Low ripples/low noise (20Hz-20MHz): < = 3mVp-p/1mVrms
Ultrafast transient response time < 50micros
Ultrafast voltage rising time up to 500micros
Current readback resolution up to 100nA
Built-in high accuracy Digital Voltmeter
Oscilloscope waveform display (DSO)
Relay out function achieves electrical isolation on terminals
Accurate battery simulation and applicable to portable battery power supplies test
LED test no overcharged current
List function achieves voltage/current output as programmed
Remote sense: The remote sense interface to compensate line voltage, increase output accuracy
Protection function: OVP, OCP, OTP
Provide free remote control software (IT9000-PV6400) with strong function saving secondary development time
Versatile interface: LAN, GPIB and USB are provided as standard
ITECH Power Supply IT6412
People who bought this item also viewed
ZIPPY Power Supply P2F-5400V
ZIPPY Power Supply R2W-6460P-R
Delta Power Supply GES-N1K
Fuji Servo Motor GYC751DC1-CA-B
Danfoss Transmitter 061B200966
Omron PLC CPM1A-TS101
Sanyo Denki Fan 9LG0912S4002
ABB Electric Motor M2QA80M4B 0.75KW
Winyao NIC Card WY546DF
SEMIKRON IGBT Module SKM300GM12T4
Pilz Relay 775600
Delkor Battery Calcium 55041
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTac Solenoid Valve 4V110M5BI
Banner Sensor Q4XFKLAF310-Q8
Eaton Moeller Circuit Breaker NZMN3-ME220
Recent related posts
-
05/31/2022
How Do I Test the Power Supply in My Computer?
Testing a power supply is an important step when troubleshooting many issues, most obviously when your computer is having trouble starting.
-
06/29/2020
How to deal with compressor stuck cylinder
How to deal with compressor stuck cylinder The compressor jamming cylinder means that the shaft of the compressor is stuck, and the compressor cannot rotate at this time. The cause of the compressor jamming cylinder is either the lack of refrigeration oil, insufficient lubrication and increased friction, or the presence of dust or impurities in the pipeline, which causes the moving surface to be stuck, or the pure mechanical failure causes the compressor to be stuck.
-
08/15/2020
Precautions during the use of air-cooled refrigerators
Before using the air-cooled chiller, you can carefully count the operating data of the equipment, and then based on these operating data, you can make a basic judgment on the operating status of the equipment,
-
06/14/2020
Which air cooling effect is better than air conditioning
The air energy heat pump cooling and heating machine is the same as the air conditioner, which can both heat and cool. The heating function is the strength of the air energy cooling and heating machine, and the effect is naturally needless to say. But wha 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠
-
08/21/2020
Tips on Air Conditioning Extension Tube
Many friends know that if the air conditioner is installed, there will be an extra charge, and this fee does not seem to be low, but you don’t know that after the air conditioner connecting pipe is extended to a certain distance,
-
09/08/2022
Brushless Vs Brushed Motor
The following article introduces some differences between brushed motors and brushless motors in terms of working principle and performance, hoping to deepen your understanding of them.
-
06/20/2020
The main reason for the slow heating of air conditioners
There are several reasons for the slow heating of air conditioners: The dirt of the transpiration device and the condenser is too thick, which will cause air flow blockage, affect the heat declaration, and make the air conditioning heating a big discount. The filter is not cleaned for a long time<img src="{{media url="The_main_reason_for_the_slow_heating_of_air_conditioners.jpg"}}" alt="" />
-
09/15/2020
Reasons and necessity of overhaul of oil-injected twin-screw air compressor
The structure of the main engine (also known as the head) of an oil-injected twin-screw air compressor is usually composed of a pair of mutually meshing screws, main engine casing, high-pressure end and end cover, and low-pressure end and end cover.
-
11/12/2021
Different Types of Pressure Transmitters, Working Principle, and How to Select Pressure Transmitter
Pressure transmitter is a kind of pressure measuring instrument widely used in many transmitters. It is widely used in petroleum, chemical, metallurgy, food, electric power, medicine, papermaking, textile and other industries.
-
06/13/2020
Global Refrigeration Compressor Market Overview 2020: Emerson, HITACHI, GMCC, Huangshi Dongbei, Landa
The market study namely Global Refrigeration Compressor Market 2020 by Manufacturers, Regions, Type and Application, Forecast to 2025 shows a focused situation of key industry players combined with their market share, deals, and development prospects.