ITECH Power Supply IT6512
People who bought this item also viewed
Eaton SANTAK Power Supply C1KRS
Delta Power Supply DRP024V120W3BN
Delta Power Supply DPS-550AB-11 A
Yaskawa Servo Motor SGM7G-30AFA6C
Allen Bradley Servo Drive 2094-SE02F-M00-S1
Danfoss Transmitter 060G2065
SUNON Fan KDE2408PTB1
LEXY Electric Motor W6570B
SAMSUNG RAM Card M471A1K43DB1-CTD
Beckhoff Terminal Box Module IL2301-B110
Panasonic Battery LC-P127R2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Daikin Compressor JT170BCBY1L
Recent related posts
-
11/24/2022
Classification of Flame Detectors
Burning generates smoke and releases heat, thanks to which, smoke detectors are invented to protect the people and properties.
-
09/02/2020
164 technical questions and answers about pumps, just read this one!
1. What is a pump? Answer: The pump is a kind of machinery that converts the mechanical energy of the prime mover into pumping liquid energy.<br></br>
-
07/20/2023
What is a Water Source Heat Pump (with Water Source Heat Pump Diagram)
A water source heat pump (WSHP) is an HVAC system that uses the natural heat in water to provide heating, cooling, and hot water for commercial and residential buildings.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/26/2020
Analysis of common faults and solutions of air-conditioning compressors
The air conditioning compressor is the heart of the refrigeration system and the power source for the refrigerant to circulate in the system. The basic working principle of the refrigeration system mainly includes the four processes of compression, condensation, throttling and evaporation.
-
01/07/2021
What caused the broken refrigerator compressor
What caused the broken refrigerator compressor It is normal for a refrigerator to fail after being used for a certain period of time. Most failures can be easily resolved, but compressor damage is not always necessary. The compressor is the heart of the 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ
-
09/11/2020
Electric valves have the advantages of easy assembly and low failure rate, becoming the mainstream of the market
In terms of operating efficiency and saving energy consumption, the use of automatic control valves is an indispensable part. The manual valves and pneumatic valves commonly used in traditional industries are not as good as electric valves in terms of installation cost and efficiency.
-
07/20/2020
What brand of refrigerator compressor is the best? Ranking of eight refrigerator compressor brands
Do you know what is the most important part of the refrigerator? Of course, it is the compressor. The refrigerator can work normally because of it. It can be said that the compressor is the core component of the refrigerator.
-
03/04/2021
What is servo motor brake
Servo motor brake, also known as holding brake, is a component of power release. Generally, the servo motor with brake is integrated with the motor. Generally, DC24 V power supply is used. It is mainly used to lock the rotor shaft of servo motor after power off.
-
09/06/2020
How to choose an air compressor in the food industry
Compared with other production-oriented industries, food safety is more important in the food industry. When choosing an air compressor, choose oil-free air compressors, which are also screw type, in order to ensure product quality.