Material: E-ETFE
Inlet/Outlet diameter: 50/40
Power: 5 HP
Frequency: 50 Hz
JK Magnet Pump MG-E-545SSV5
People who bought this item also viewed
PAN WORLD Magnet Pump NH-100PX-F
PAN WORLD Magnet Pump NH-250PS
Becker Vacuum Pump U4.20/1
GRACO Diaphragm Pump 233777
WALRUS Water Pump TPHK8T6-2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch E2 AC-DXBC1059
LS Servo Drive APD-VN04N
Yuci Vane Pump PFED-42056-006-1DT
Recent related posts
-
08/09/2020
Leak detection, drainage, and vacuum operation methods of the refrigeration system in the computer room
The refrigeration system is indispensable for the computer room. Leak detection, sewage discharge, and vacuuming in the refrigeration system protect the refrigeration system so as to prevent the dirt in the system from entering the compressor and throttle valve
-
09/10/2020
Air compressor selection and energy saving methods
I. Overview Among many commonly used energy sources, compressed air can be said to be one of the popular energy sources second only to electricity. Although the use of compressed air has not yet penetrated into ordinary households like electricity,
-
07/10/2020
Hitachi compressor features:
Hitachi compressor features: 1. Whether Hitachi compressors use refrigerant R22 or the new chlorine-free refrigerants R134a, R404A, R507A and R407C, they can operate smoothly and reliably.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/19/2022
Types of Linear Motors
linear motor as the name suggests, is a motor that produces linear motion. The working principle of linear motor
-
06/22/2020
What's the matter with air conditioning and cooling without heating
What's the matter with air conditioning and cooling without heating 1.First, it may be because the vents of the indoor unit and outdoor unit are blocked by something, or a lot of dust has accumulated on the filter inside the air conditioner; 2. It may be because the heat blown from the air conditioner is seriously lost; 3 2. It may be because the amount of refrigerant in the air conditioner is too small, which leads to a great reduction in the heat exchange efficiency, so that the air conditioner does not heat. <img src="{{media url="magefan_blog/What_s_the_matter_with_air_conditioning_and_cooling_without_heating3.jpg"}}" alt="" />
-
03/17/2021
Instructions for 3 axis stepper motor driver
The high-speed performance of the motor depends on the power supply voltage, the output torque of the motor on the current setting value.
-
07/02/2020
How is the compression process of the PFM compressor
How is the compression process of the PFM compressor One of the PFM compressors is a scroll compressor. How is its compression process completed? We can find the answer in this article. First of all, we must know that there are two scrolls in the upper part of the PFM compressor, a moving scroll and a static scroll.
-
08/30/2020
Observation on the evolution of the compressor industry
Some of the changes in the compressor market are like summer storms, such as price rises and falls, and sales volume. Some changes are like the drizzle in spring, moistening things silently.
-
08/17/2020
What is the reason for the excessive leakage of the refrigeration compressor
1. Insufficient oil flow, increase the oil supply appropriately; 2, the assembly sequence of the refrigeration compressor stuffing box is unreasonable and should be assembled according to the procedure;